Major tech MT150 Manuel d'instruction - Page 10

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Major tech MT150. Major tech MT150 12 pages. 50m laser distance meter

Major tech MT150 Manuel d'instruction

9.4. Switching BLUETOOTH On

Hold down the
the display. Then you can use our Meterbox APP installed on your
phone to connect with this instrument.

9.5. Switching BLUETOOTH Off

Hold down the
the display. BLUETOOTH is disabled when the instrument is turned
off.

10. Measuring Conditions

10.1. Measuring Range
The range is limited to Technical Specifications.

10.2. Target Surfaces

Measuring errors can occur when measuring toward colorless
liquids (e.g. water) or dust free glass, Styrofoam or similar
semi-permeable surfaces. Aiming at high gloss surfaces may
deflect the laser beam and lead to measurement errors. Against
non-reflective and dark surfaces the measuring time may increase.

10.3. Care

Do not immerse the instrument in water. Wipe off dirt with a damp,
soft cloth. Do not use aggressive cleaning agents or solutions.
Handle the instrument as you would a telescope or camera.
10.4. Troubleshooting – Causes and Corrective Measures
Code
Cause
208
Received signal too weak,
measurement time too long.
Distance>50m
252
Temperature too high
253
Temperature too low
255
Hardware error
10
button until the Bluetooth symbol disappears in
Unit
button until the Bluetooth symbol disappears in
Unit
Corrective Measure
Use target plate
Cool down instrument
Warm up instrument
Switch on/off the device several times,
If the symbol still appears, please
contact your dealer for assistance.