Centurion D3 Manuel rapide - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel rapide pour {nom_de_la_catégorie} Centurion D3. Centurion D3 2 pages.
Également pour Centurion D3 : Manuel rapide (3 pages)

Centurion D3 Manuel rapide
D3/D5 OPERATOR PROGRAMMING GUIDE
Three points to consider before programming the controller:
1
When the gate is in the CLOSED position the sensor magnet should be at least 500mm
from the sensor. The gap between the sensor and the magnet must be between
13 - 20mm. The arrow on the magnet must point in the direction of the sensor.
2
Wiring of the motor must be correct according to the gate opening direction.
Closing to the Left: Black wire to the outside. (Left of the Blue wire).
Closing the the Right: Blue wire to the outisde. (Right of the Black wire).
3
Ensure that you have effective endstops at both ends of the gate.
(Refer to Installation manual)
Battery Terminals
L2
L1
Test
Status
Battery Power
CP80
Electrical Power
Set Link
CP80
Sensor
"Manual Override"
PROGRAMMING MODE:
1
Disconnect electrical charge and negative wire to battery, from the controller card.
2
Position Set link over both Set Pins.
3
Replace all power to the controller card.
4
Ensure that L2 is ON (L1 must be OFF).
5
Release the Manual Override, move the gate to the half open position and re-engage Manual
Override.
6
Press TEST button once. L1 will start flashing, once per second. L2 is OFF.
7
Press and hold the TEST push button until the STATUS LED illuminates. Release TEST push button.
The gate will start its automatic setup by OPENING. At the OPEN endstop the gate will stop and
reverse slowly. At the CLOSED endstop the gate will stop and reverse. The gate will open quickly
until the magnet reaches the origin sensor. When the gate reaches the origin sensor it will open
slowly. At the OPEN endstop the gate will stop and reverse. The gate will close quickly until the
magnet reaches the origin sensor. At the CLOSED endstop the gate will stop and reverse. The gate
will open to the pedestrian opening point.
8 8
Press TEST push button once and release.
8 9
Ensure that L2 is ON (L1 should be OFF). This is the end of the automatic setup routine.
AUTO CLOSE
AUTO CLOSE
Ensure controller is in programming mode (L2 is ON).
Press and hold the TEST button. L1 will start flashing; once pause, once - twice, when L1 flashes
twice release the TEST push button.
L1will continue to flash twice. L2 will be OFF.
Press TEST button and wait until the STATUS LED flashes once.
Release TEST button.
L2 will illuminate.
AUTO CLOSE TIME is now ON and set to 15 seconds (Factory default).
Remove the SET link from the set jumper and store the link on one of the pins of the jumper, if
you want to exit program mode.
AUTO CLOSE TIME
AUTO CLOSE TIME
Ensure that the controller is in programming mode (L2 is ON).
Press and hold TEST button. L1 starts flashing:1 pause, 1-2 pause 1-2-3-, release TEST button.
L1 continues to flash 3 times, press TEST button to set time (One flash of STATUS is equal to
one second of auto-close time).
Release the TEST button after the STATUS LED has flashed the required number of times.
L2 will illuminate.
AUTO CLOSE TIME is now set; remove the SET link from the set jumper and store the link on
one of the pins of the jumper, if you want to exit the program mode.
COLLISION SENSITIVITY
COLLISION SENSITIVITY
Ensure the controller is in programming mode (L2 is ON).
Press and hold the TEST button.
L1 starts flashing; 1 pause, 1-2 pause,1-2-3 pause, 1-2-3-4 pause, 1-2-3-4-5 pause, 1-2-3-4-5-6
pause, 1-2-3-4-5-6-7, release TEST button.
L1 continues flashing 7 times and L2 will go OFF.
Press TEST button and wait for STATUS to flash;
1 flash = High sensitivity (Gate stops easily)
1 pause, 1-2 = Medium sensitivity (Gate stop with reasonable effort)
1 pause, 1-2 pause, 1-2-3 = High sensitivity (Gate stops with difficulty)
Release the TEST button after required number of flashes.
L2 will go ON.
COLLISION SENSITIVITY is set; remove the SET link from the set jumper and store the link on
one of the pins of the jumper, if you want to exit program mode.