5. Specifications
Function
AC True RMS Current
Over range protection: Maximum input 400A.
Accuracy specified from 5% to 100% of the measuring range.
Frequency Response: 50Hz to 60Hz True RMS.
Inrush current Maximum Input: 400A Inrush current Sensitivity: >2A.
Function
DC Current
Over range protection: Maximum input 400A.
Function
DC Voltage
Maximum input: 1000V DC
Function
AC True RMS Voltage
(with VFD)
Variable frequency Drive TEST AC voltage range: 100V---600V.
AC voltage bandwidth: 50 to 1000Hz (sine) 50/60 (all wave)
Accuracy specified from 5% to 100% of the measuring range
Maximum Input: 1000V AC RMS.
PEAK Maximum Input: 1000V
Function
Resistance
Input Protection: 300V DC or 300V AC RMS
Range
Resolution
40.00A
10mA
100mA
400.0A
Range
Resolution
40.00A
10mA
100mA
400.0A
Range
Resolution
4.000V
1mV
10mV
40.00V
100mV
400.0V
1V
1000V
Range
Resolution
4.000V
1mV
10mV
40.00V
100mV
400.0V
1V
1000V
Range
Resolution
400.0Ω
0.1Ω
1Ω
4.000kΩ
10Ω
40.00kΩ
100Ω
400.0kΩ
1kΩ
4.000MΩ
10kΩ
40.00MΩ
Accuracy ±(% of reading+digits)
±(2.0% + 8 digits)
±(2.5% + 8 digits)
Accuracy ±(% of reading+digits)
±(2.0% + 8 digits)
±(2.5% + 8 digits)
Accuracy ±(% of reading+digits)
±(1.0% + 3 digits)
±(1.0% + 3 digits)
±(1.0% + 3 digits)
±(1.2% + 3 digits)
Accuracy ±(% of reading+digits)
±(1.2% + 5 digits)
±(1.2% + 5 digits)
±(1.2% + 5 digits)
±(1.5% + 5 digits)
Accuracy ±(% of reading+digits)
±(1% + 4 digits)
±(1.5% + 2 digits)
±(1.5% + 2 digits)
±(1.5% + 2 digits)
±(2.0% + 5 digits)
±(3.0% + 8 digits)
7