5.12. Measuring Active Power (W) / Power factor (PF)
1. Single Phase Power Measurement
Step 1: Set the rotary switch to the "W" position.
Step 2: Connect the Red test lead to the Line conductor, and the Black
test lead to the Neutral conductor.
Step 3: Press the trigger to open the transformer jaws and clamp one
conductor only, make sure that the jaw is firmly closed around
the conductor.
Step 4: Using the Mode key to choose the "W/PF" mode.
Note:
The meter offer AC power measurement mode only.
Active power sign :
No sign :
"_" sign :
Power factor sign :
No sign :
"_" sign :
Overrange display :
± OL kW :
OLU:
Active Power >600 V or < -600 V.
Indicates the power flows from the power source to the
load.
Indicates the power flows from the load to the power
source.
The phase of the current signal is lagging behind the
voltage signal (inductive load).
The phase of the current signal is leading the voltage
signal (capacitive load).
Active Power >600 kW or < -600 kW.