9.7 Hold the case and backplate
over the
window
aperture
and the outer cover
on the
outside.
Fit and tighten
the 4 mm X 40 mm
long screws
sufficiently
to create
a seal on
the glass and secure
the fan in position.
Do
not overtighten.
9,8 Fit the mains
cable through
the hole in
the fan case and make connections
to the
terminal
block after releasing
it from the
backplate
(see Section
4 and Fig. 5).
9.9 Refit the terminal
block,
fan and motor
assembly,
which
must
be inserted
under
the
tabs on the backplate
and be pulled
to the
left whilst
tightening
the fixing
screws,
followed
by the module
and grille.
Do not
overtighten
the grille
retaining
screw.
9.2 Dismantle the Loovent or Humidivent
(see section 5.1 and Fig. 2). For window
installation, do not separate the case and
backplate.
9.3 Drill a hole in the fan case for the mains
cable and knock out the holes for fixing to
the window kit (see Fig. 15).
9.4 Remove the backdraught flap from the
backplate (see Figs. 17 and 18) as flaps are
provided in the outer cover.
9.5 To reduce the load on the glass during
the final assembly into the window, take the
two 4 mm X 40 mm long screws from the
fixing pack and assemble them a few turns
and release them from the holes in the outer
cover.
9.6 Cut the sealing strip provided to length to
fit around the edge of the outer cover and fit
it with the long lip on the outside and the
joint at the bottom.
12