Major tech MTD73A Manuel d'instruction - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Major tech MTD73A. Major tech MTD73A 20 pages. 800a ac true rms digital clamp meter

Major tech MTD73A Manuel d'instruction
Function
DC Voltage
(Auto
Ranging)
Input impedance on 400mV range ˃ 40MΩ all other ranges
10MΩ. Overload protection 1000V DC or 750V AC peak value
Function
Resistance
(Auto
Ranging)
Input Protection: 250V DC or 250V AC RMS
Note: a. On 400Ω range, short the test leads to measure lead
resistance, then subtract the value from the real measurement
b. When measuring resistance over 1MΩ, it is normal that the
reading reacts slowly, wait until reading is stable.
Warning DO NOT apply voltage to this range
Range
400mV
4.00V
40.0V
400V
600V
Range
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
Resolution
0.1mV
1mV
10mV
0.1V
1V
Resolution
0.1Ω
1Ω
10Ω
100Ω
1kΩ
10kΩ
Accuracy
(% of reading +
digits)
+1.0% of rdg +
5digits
+0.5% of rdg +
5digits
Accuracy
(% of reading +
digits)
+0.8% of rdg +
5digits
+0.8% of rdg +
3digits
+1.0% of rdg +
5digits