Centurion R5 Manuel d'installation rapide - Page 13

Parcourez en ligne ou téléchargez le pdf Manuel d'installation rapide pour {nom_de_la_catégorie} Centurion R5. Centurion R5 17 pages. Rotary swing gate operator
Également pour Centurion R5 : Manuel d'installation rapide (19 pages), Manuel d'installation rapide (2 pages)

Centurion R5 Manuel d'installation rapide
At this moment release the TEST button to select feature
number 2. (L2 will turn off, and L1 will keep on flashing 2 times
and pausing to indicate that feature number 2 is selected).
NOTE: The STATUS of the Feature is not changed yet, the
feature has only been selected to be changed!
If an incorrect Feature is selected, then remove and re-
apply power and repeat the procedure.
To change the STATUS value of a Feature: (IM page 31)
Press and hold the TEST button while monitoring the

STATUS light:

(Continues from above example to set outoclose to ON status).
The L1 light will flash once and pause,
At this moment release the TEST button to give a
STATUS value of 1. The AUTOCLOSE feature has been set to
ON
NOTE: Only after setting the STATUS, would the
AUTOCLOSE be turned ON.
(L2 will come back on, indicating that the STATUS has been
set.)
To change the COUNT value of a Feature: (IM page 31)
Press and hold the TEST button while monitoring the
STATUS light:
After a slight pause, the STATUS light will start flashing . . . . . . .
regularly:
Flash (1), Flash (2), Flash (3), Flash (4), Flash (5),
Flash (6) ................ Flash (9), Flash (10).
At this moment release the TEST button to give a COUNT . . . . .
value of 10. This could for example be the preflash time.
(L2 will come back on, indicating the COUNT value has . . . . . .
been set). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
E
P
XIT
Remove the SET link.
All manuals and user guides at all-guides.com
ROGRAMMING
M
ODE