2. Press the "DATA HOLD" button to return to normal
operation.
Auto Power Off
The auto off feature will turn the meter off after 15
minutes.
Replacing The Fuses
1. Disconnect the test leads from the meter.
2. Remove the protective rubber holster.
3. Remove the battery cover (two "B" screws) and the
battery.
4. Remove the four "A" screws securing the rear cover.
5. Lift the center circuit board straight up from the
connectors to gain access to the fuse holders.
6. Gently remove the old fuse and install the new fuse
into the holder.
7.
Always use a fuse of the proper size and value
(0.2A/250V fast blow for the 200mA range).
8. Align the center board with the connectors and gently
press into place.
9. Replace and secure the rear cover, battery and battery
cover.
WARNING: To avoid electric shock, disconnect the test
leads from any source of voltage before removing the fuse
cover.
Battery Replacement
1. Both for the transmitter or receiver, when the "Low
battery indicator" is lit, it is necessary to replace the
battery. Measurements may still be made several hours
after the low battery indicator.
2. Remove the bottom cover and secure the screw.
3. Replace old battery with fresh two 1.5V AAA or 9V type
battery.
4. Replace the bottom cover and secure the screw.