- 1. Installation/Maintenance/Use
- 2. Front Cover Removal
- 3. Mechanical Installation
- 4. Recessing Fans in the Wall
- 5. Surface Mounting Fans on Wall
- 6. Recessing Fans in Ceiling
- 7. Surface Mounting Fans on Ceiling
- 8. Electrical Installation
- 9. Optional Modules for Icon/Eco 230V
- 10. Troubleshooting Tip
- 11. Maintenance
- 12. Warranty
- 13. Range of Optional Modules
Maintenance
SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT FROM THE POWER SUPPLY BEFORE
REMOVING THE COVER.
Warranty only covers the fan, not the reinstallation of this if required.
When installed according to these instructions the iCON Domestic Fans are completely safe.
The materials used do not constitute a hazard. The module covers are made of a flame
retardant material.
Cleaning
The external housing of the fan can be wiped with a damp cloth. Do not use household
cleaners containing abrasives.
Cleaning of the internal parts such as the impeller should be carried out using a soft
brush.
Note: Always ensure that the fan unit is isolated from the power supply before inserting
the brush into the impeller duct.
Never clean any parts of the fan assembly by immersing in water or using a dishwasher.
Trouble shooting Tip:
Take care not to over tighten the duct connection to the fan spigot. This can result in
restricting the free rotation of the impeller and a thermal overload of the motor could occur
causing short term fan failure. In the event of this occurring loosen the duct connection so
that the impeller rotates freely within the spigot.
The motor is fitted with an automatic reset after approximately 15 minutes and will restart
the fan when reconnected to the module controller and mains supply.
Warranty
Applicable to units installed and used in the United Kingdom. Airflow guarantees the iCON,
iCON eco fan units and iCON modules for 2 YEARS from date of purchase against faulty
material or workmanship. Extended to 3 when registered @ airflow.com. Warranty only
covers the fan, not the reinstallation of this if required.
In the event of any defective parts being found, Airflow Developments Ltd reserve the right
to repair or at our discretion replace without charge provided that the unit:
1. Has been installed and used in accordance with the fitting and wiring instructions
supplied with each unit.
2. Has not been connected to an unsuitable electrical supply.
3. Has not been subjected to misuse, neglect or damage.
4. Has not been modified or repaired by any person not authorised by Airflow
Developments Ltd
5. Has been installed in accordance with latest Building Regulations and IEEE wiring
regulations.
Airflow Developments shall not be liable for any loss, injury or other consequential damage,
in the event of a failure of the equipment or arising from, or in connection with, the
equipment excepting only that nothing in this condition shall be construed as to exclude or
restrict liability for negligence.
This warranty does not in any way affect any statutory or other consumer rights.