Britannia K7088ASC - 100 Instructions pour l'utilisateur - Page 3
Parcourez en ligne ou téléchargez le pdf Instructions pour l'utilisateur pour {nom_de_la_catégorie} Britannia K7088ASC - 100. Britannia K7088ASC - 100 8 pages.
Maintenance and service
This appliance can be a fire hazard if the grease filters are not cleaned in accordance with instructions.
Always insist on genuine spare parts.
Under no circumstances should you attempt to repair the appliance yourself. Repairs carried out by
inexperienced persons may cause injury or a more serious malfunction.
In the event of service being required for your cooker hood please contact the service helpline.
Any service work will generally entail removal of the telescopic flue assembly to access key
components including the motor. If the flue assembly has been boxed in by means of a bridging shelf or
any type of furniture this must be removed prior to our engineer's visit.
Technical
SPECIFICATION
MODEL K7088
SPEED
Air capacity cubic
metres per hour *
Pressure PA mmH
2
O
Input - watts
Noise level - dbA **
Finish
Stainless Steel
700mm, 900mm, 1000mm or 1200mm wide
Size
Controls
Electronic
Air outlet
150mm diameter
Illumination
2 x halogen lamps 20 watts
Motor
1 x 250watts (4 speeds)
Total wattage 290 watts
Mains supply
230 volts 50 Hz
Connection
via a 13 amp fused spur outlet fused at 5 amps
Electrical connections
Important: Ensure that the electricity supply is switched off
before connecting.
Your appliance must be connected to fixed wiring via the use of a
double pole switched fused spur outlet with at least 3mm contact
separation. (See technical data for fuse rating).
We strongly recommend the appliance is connected by a qualified
electrician who is a member of the N.I.C.E.I.C. or Corgi who will
comply with the I.E.E. and any local regulations.
Note: The terminology "double pole" means that both the live and
neutral supplies are switched and disconnected at the same time.
The terminations labelled SUPPLY are for the internal house wiring and
the terminations labelled LOAD are for connection for the appliance.
WARNING - THIS APPLIANCE
MUST BE EARTHED
Important: The wires in this mains lead are
coloured in accordance with the following code:-
Green/Yellow = Earth, Blue = Neutral, Brown = Live
As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings identifying the terminals in
your spur box, proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal which is marked with
the letter 'E' or by the earth symbol or coloured green or green and yellow.The wire which is coloured
blue must be connected to the terminal which is marked with the letter 'N' or coloured black.The wire
which is coloured brown must be connected to the terminal which is marked with the letter 'L' or
coloured red.
1
2
3
4
285 440 600 700
300 470 630 750
36 43
46 47
34
41
45
46
160 190 215 245
125 160 200 250
66 69
51 58
40
49
56
59
*
Performance data according to Standard EN61591,
Free air delivery.
Noise level according to Standard IEC60704-2-13
**
method.
Technical Data
Fuse rating:
5 AMP
2