Installation
Height above hotplates
For best performance we suggest that the hood is installed at a distance between 65cm to75cm from
the hotplate surface. Under no circumstances should the hood be installed lower than 65cm above the
hotplate surface.
Ducting information
This hood is designed for ducting out, i.e. duct to an outside wall.To obtain the best possible extraction
performance use 150mm diameter ducting.Wherever possible utilise rigid circular pipe or "Mega duct"
ducting - both types are available via your Britannia dealer. Do not use expanding concertina type
ducting as this is not smooth on the interior and can cause air flow restrictions. Do not use ducting
that has a smaller diameter than 150mm as this will reduce extraction rates and can increase noise
levels. Please note ducting kits and ducting components are optional accessories and have to be ordered
- they are not supplied with the hood.
One metre
length pipe
Code DUCT/1100-6
Two metre
length pipe
Code DUCT/1200-6
One metre and two
metre length pipes can be
cut to the desired length
Wall vent with
gravity flaps
Code DUCT/6900
Maximum length of ducting run
4 metres with 1 x 90 degree bend
3 metres with 2 x 90 degree bends
2 metres with 3 x 90 degree bends
Note: the shorter the ducting run and the least number of bends gives the best extraction performance.
Warning: Any ducting used must be fire retardant.
Unpacking the hood
On some models components are packed inside the polystyrene protection pieces.
Do not throw away the box and packaging until installation is fully completed.
Installation
ATTENTION:
The appliance should be installed by a qualified electrician or competent person.
1 Before fixing the hood install the ducting run for air evacuation to the outside. See fig. 1 . Ducting can
be run through the rear wall or through the ceiling.
2 Turn off electricity before preparing a suitable power supply. For the electrical connection requirements
follow the details on page 2.
3
3 Remove the metal grease filters. See fig. 2
Megaduct Ducting Kit
90 degree bend
Code DUCT/690
Pipe connector
Code DUCT/693
One metre
ducting kit
Comprising: one
metre length pipe,
wall vent and 90
degree bend.
Code DUCT/2609
horizontal
bend
Combination of 6" (150mm) circular
pipe and flat channel (220mm x 90mm)
which is ideal for running on top of
wall units or between ceiling joists.
Megaduct kit Code DUCT/2652B
Horizontal bend Code DUCT/950