JALpower D-NS SERIES Manuel de l'utilisateur - Page 13

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} JALpower D-NS SERIES. JALpower D-NS SERIES 14 pages. Solar inverter

Model
3600-NS
General Data
Dimensions (WxHxD)
Weight (kg)
Mounting
Ambient temperature range
Relative humidity
Moisture location category
Max. operating altitude
Protection degree
Environment category
External environment pollution degree
Topology
Night power consumption(W)
Cooling
Noise emision(dB)
Display
Communication
Standard warranty(years)
Model
3000D-NS
DC input Data
*
Max. DC power(W)
3900
Max. DC voltage (V)
MPPT voltage range (V)
Starting voltage (V)
Max. DC current (A)
DC overcurrent protection(A)
No. of DC connectors
No. of MPPTs
DC overvoltage category
DC connector
AC Output Data
Norminal AC power(VA)
3000
Max. AC power(VA)
3000
Max. AC current(A)
13.6
AC overcurrent protection(A)
20
Norminal AC output
AC output range
THDi
Power factor
Grid connection
21
4200-NS
5K-NS
5000-NS
347*432*145mm
14
Wall bracket
-25~60°C (>45°C derating)
0~95%
4K4H
4000m(>3000 derating)
IP65
Outdoor & indoor
Grade1、2、3
Transformerless
<1
Nature convection
<25
LCD
USB2.0; RS485 or WiFi
5/10/15/20/25 (optional)
3600D-NS
4200D-NS
5KD-NS
5000D-NS
5460
6500
4680
580
80~550
120
11 / 11
13.8/13.8
2
2(can parallel)
Category Ⅱ
SUNCLIX /H4/ MC4 (Optional)
3680
4200
4600
3680
4200
4950
16
19
21.7
22.8
24
29
35
50/60Hz; 220/230Vac
45~55Hz/55~65Hz; 180~270Vac
<3%
0.8 leading~0.8 lagging
Single phase
Model
AC overvoltage category
Efficiency
Max. efficiency
Euro efficiency
MPPT adaptation efficiency
Protection
Residual current monitoring unit
Anti-islanding protection
DC switch
AC over current protection
Insulation monitoring
Certifications&Standards
Grid regulation
Safety
EMC
General Data
Dimensions (WxHxD)
Weight (kg)
Mounting
Ambient temperature range
Relative humidity
Moisture location category
6500
Max. operating altitude
Protection degree
Environment category
External environment pollution degree
Topology
Night power consumption(W)
Cooling
Noise emision(dB)
Display
Communication
Standard warranty(years)
5000
*
* 4600 VDE-AR-N4105;4950 fro Australian;5000 for other country
5000*
** 22.8 for other country;21.7 fro Australian
**
35
3000D-NS
3600D-NS
4200D-NS
Category Ⅲ
97.8%
97.8%
97.8%
97.5%
97.5%
97.5%
>99.9%
Integrated
Integrated
Integrated (optional)
Integrated
Integrated
VDE-AR-N 4105, AS4777.2&.3, RD1699, IEC62109-2/1, VDE0126-1-1+A1, EN50438 G83/G59
IEC62109-1&-2, AS3100
EN 61000-6-1,EN 61000-6-2,EN 61000-6-3,EN 61000-6-4, EN 61000-3-11, EN 61000-3-12
347*432*145mm
14
Wall bracket
-25~60°C (>45°C derating)
0~95%
4K4H
4000m(>3000 derating)
IP65
Outdoor & indoor
Grade1、2、3
Transformerless
<1
Nature convection
<25
LCD
USB2.0; Wi-Fi or RS-485
5/10/15/20/25 (optional)
5KD-NS
5000D-NS
97.8%
97.8%
97.5%
97.5%
22