Green Eco Pro Ultra 90 Manuel d'instruction - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Green Eco Pro Ultra 90. Green Eco Pro Ultra 90 15 pages. Coolant purification systems

Operating Guide & Safety – Page 1
1. Coolant Volume Adjustment
1.1 With switch in the Off position, connect the air supply hose. Check the
incoming air pressure by reading the gauge. Factory default setting at 35
P.S.I. If the actual air pressure is above/below the factory recommended
value, adjust accordingly. The air pressure regulator is located under the top
cover. To adjust the air pressure, pull the cap in the upward position. See the
illustration above. Lowering the air pressure will cause the flow of coolant to
stop as well as the pump to malfunction.
NOTE: To get a proper reading of air pressure gauge please turn the
coolant volume switch On/off then on again.
2.1 In the event of the pump clogging up or if the unit is sitting idle for a period of
time, this may cause the pump to malfunction. You may have to adjust the air
pressure above 35 P.S.I. Once the pump resumes operation, readjust the air
pressure to the factory recommended value of
35 P.S.I.
.
2. The relocation of unit
1.
In case a relocation is required, be sure to
shut off the oil outlet valve. Once it is moved to
a desired location, please relevel this unit.
When foam or bubbles occurred in the coolant,
please stop operation of this unit or turn the
coolant volume adjustment down.