PERFORMANCE DATA SHEET
Base Grille Water Filtration System
Model WF-NL240/NL240
Capacity
240 Gallons
(908 Liters)
Model WF-L400/L400
Capacity
400 Gallons
(1514 Liters))
(_
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste
and Odor, Particulate
Class I1'; and against
NSF/ANSI
Standard
53 for the reduct on of Lead.
This system
has been tested according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSI
Standards
42 and 53..
Substance
Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
_>50%
Particulate Class I1"
_>85%
Contaminant
NSF Reduction
Reduction
Requirements
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
1.9 mg/L
833,333/m L
97.4%
97.4%
88.0%
95.1%
2.0 mg/L _+10%
0.05 mg/L
0.05 mg/L
At particles/mleast
10,000L
100,000/m L**
40,667/m L
Maximum
Average
Effluent
Effluent
Average
Influent Challenge
Minimum %
Average %
Influent
Concentration
Reduction
Reduction
Lead: @ pH 6.5
0.01 mg/L
0.15 mg/L***
Lead: @ pH 8.5
0.01 mg/L
0.15 mg/L***
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted.
Temp. = 63°F (17.2°C).
•
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
•
Model WF-NL240: Change cartridge at least every 6 months.
Use replacement cartridge NL240, part #4396508.
2008 suggested retail price of $32.99 U.S.A./S44.95 Canada.
Prices are subject to change without notice.
Model WF-L400: The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended
that you
replace the filter. Use replacement cartridge L400, part
#4396508. 2008 suggested retail price of $32.99 U.S.A./
$44.95 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection before or after
the system.
0.15 mg/L + 10%
0.001 mg/L
0.001 mg/L
99.3%
99.3%
0.15 mg/L _+10%
0.003 mg/L
0.001 mg/L
97.9%
99.0%
Flow = 0.5 gpm
(1.9 Lpm). Pressure
= 60 psig (413.7
kPa).
Note that while the testing was performed under standard
laboratory conditions, actual performance may vary.
Refer to the front cover or "Assistance or Service" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application
Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 1OO°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm (1.9 Lpm) @ 60 psi.
* Class II particle size: >1 to <5
** Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
*** These contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
® NSF is a registered trademark
of NSF International.