Century K3149-1 Manuel - Page 12
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Century K3149-1. Century K3149-1 18 pages. Wheel charger 11860 40/20/2/200, 6/12v w/test 11861 60/40/2/250, 6/12v w/test 11862 60/40/30/225, 6/12/24v
The following instructions or the associated LENGTH OF
CHARGE TIME CHARTS (60 amps down to 2 amps, one
for each charging range) will allow you to determine how
long it will take to bring a spec
the charger is so equipped, a green light on the charger
will indicate the battery has become fully charged.
CAUTION
Batteries that have 25% charge or less can easily
freeze and should be charged at once, but DO NOT
CHARGE A BATTERY THAT IS ALREADY FROZEN.
1.
Determine the present level of charge in the battery
with a hydrometer or electronic percent-of-charge
tester.
2.
Determine the size of the battery in
RESERVE CAPACITY. If these ratings are not printed
on the battery, contact your local battery dealer for
this information. These are the only ratings that can
be used to determine length of charging time. Then
either use the formula in step 3 or use Table 2 plus
Table 3, through Table 9 for the charging rate
capabilities of this charger.
3.
Use the battery rating, the charge level of the battery,
and the amp setting to be used on the charger (see
Table 2), in the formula provided below.
Model
6V HIGH
K3149-1
40 Amp
K3150-1
60 Amp
K3151-1
60 Amp
battery to full charge. If
AMP HOURS or
Hours
X
1.25 =
to
Charge
Table 2. Charge Amp Settings
12V LOW
12V MED .
2 Amp
20 Amp
2 Amp
40 Amp
40 Amp
EXAMPLE:
Battery's Present State of Charge:
Percent of Charge NEEDED: 100% – 25% =
Expressed as a Decimal: = .75
Amp setting on Charger: 10
Amp-Hour Rating of Battery: 60
60 X .75
X 1.25 = Hours to Reach Full Charge
10
45
X 1.25 = Hours to Reach Full Charge
10
4.5
X 1.25 = Hours to Reach Full Charge
:
NOTE
If the battery is rate d in RESERVE CAPACITY,
use the following formula to convert reserve
capacity to amp-hours.
Reserve Capacity
+ 15.5 = Amp Hour Rating
2
24V HIGH
12V HIGH
40 Amp
60 Amp
60 Amp
30 Amp
25%
75%
START
200 Amp 12V
130 Amp 6V
250 Amp 12V
185 Amp 6V
225 Amp 12V
160 Amp 6V
12