if codespermitanda separate ground
wireis used, i t is recommended thata
qualified
electrician determine that the
ground path is adequate.
Do Not ground to a gas pipe.
Check with a qualified eJectNcian if you
are not sure cooktop is properly
grounded,
Do Not have a fuse in the neutral or
grounding circuit,
The downdraft cooktop must be
connected to the proper electrical voltage
and frequency as specified on the
model/serial rating plate. The model/serial
rating plate is located on the bottom of the
cooktop.
[_ A four-wire or three-wire, single-phase,
240-volt, 60-Hz, AC-only electrical
supply is required on a separate
30-ampere circuit, fused on both sides
of the line.
[_ A time-delay fuse or circuit breaker is
recommended. The fuse size must not
exceed the circuit rating of the
appliance as specified on the
model/serial rating plate.
[_ CONNECT WITH COPPER WIRE
ONLY.
Connected directly to the fused
disconnect (or circuit breaker box)
through flexible, armored or non-
metallic sheathed, copper cable (with
ground wire).
[_ Flexible armored cable should connect
cooktop directly to the junction box.
[_ Fuse both sides of the line.
[_ Locate the junction box to allow as
much slack as possible between the
junction box and cooktop so that the
downdraft cooktop can be moved if
servicing is ever necessary.
[_ A U.L.-listed 1/2" (12.7 mm) conduit
connector must be provided at the
junction box.
The recommended
minimum copper
wire size is No.olO gauge. However,
wire sizes and connections must conform
to the requirements of the National
Electrical Code, ANSI/NFPA 70 -- latest
edition*, or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and 22.2
No. 0-M91 - latest edition** and all local
codes and ordinances. Wire sizes and
connections must conform with the rating
of the cooktop.
Copies of the standard listed may be obtained from:
* National Fire Protection Association
Batteryrnarch Park
Quincy, Massachusetts 02209
** Canadian
Standard
Association
178 Rexdale Boulevard
Etobieoke,
Ontario
MgW 1R$
The wiring diagram is located on the
bottom of the cooktop.
Twist-on connectors and U.L.-Iisted 1/2"
(12.7 mm) conduit connector are not
provided.
m
Remove shipping materials andtape
from cooktop.
2m
The blower is set to vent straight out
the back of the cooktop.
To vent to the [eft side, right side or down
through the bottom of the cabinet, add an
elbow to the blower assembly exhaust vent.
it may be easier to connect appliance
cable to junction box before inserting
cooktop into cutout. See "Electrical
connections," Page 7.
Excessive Weight Hazard
Use two or more people to move
and install cooktop.
Failure to do so could result in
back or other injury.
Lift entire
cooktop
up from cutout
when positioning
cooktop
in
countertop
opening.
S_
Insert downdrafl cooktop into cutout.
Checkthat:
[_ cooktopis centered in cutout.
[_ front edge of downdrafl cooktopis at least
1-1/2" (38.1 mm) from front edge of
countertop and parallelto countertop.
[_ rear edge of cooktopis at least 3/4"
(!9.! mm)from rear wall as recommended.
[_ side edge of cooktop is at least 6 inches
(!5.2 cm) from side wall.
Connect vent system. See "Venting
requirements," Pages 4-5. Use duct tape to
seal all ioints. Vent must end with a wall or roof
cap outside the building.