Switch on unit (Position „MAN" at selector switch) and check, if filter housings are
filling with water
7.1 Initial operation with waste water hose with proximity switch
As an option, a waste water hose with proximity switch for electrical and automatic
On/Off switch function is available.
Before the initial operation of the waste water pump or after a long period of stagnation,
check that the shaft rotates freely when turned by hand. To this put a screwdriver in the
notch of the shaft end on the fan side and move the shaft. The strong initial rotational
resistance of the new pumps will come loose after running.
Fill waste water pump fully through vent connection
Tighten the cap nut of the filter housing by hand