EMBEDDED DOME INSTALLATION
Step 1: drill a hole on ceiling
At the installation center of ceiling drill a hole of
3 m m d i a m e t e r, i n p u t s e l f - t r a p p i n g s c r e w t o
positioning-ruler hole, and then fix it on ceiling.
Use pencil and positioning-ruler drawing a circle,
dig away stuff.
Step 3: set dome
Set dome bottom DIP switcher (SW1 and SW2) to
confirm control-protocol and dome address, similar
with label setting or switcher setting.
Step 5: install dome
Insert 3 screw units into the
upper bracket hole, just like the
picture directing, confirm all
screws are tightened in locating
slot.
Turn
CEILING MOUNT DOME INSTALLATION
Step 1: open hole on ceiling
According to bracket hole size, use pencil and
positioning-ruler drawing a circle (Φ40mm), dig away
stuff.
At the edge of circle, drill 3 holes (Φ6mm) matched
with 3 holes of bracket, then fill M6 anchor-screws on
each hole (anchor-screws are offered by customer).
AC 1
Power supply
GND
24VAC
AC 2
Monitor or other
video-input
devices
Video out
Control signal
RX+
RS-485(Pelco)
RX-
Step 2: install embedded bracket
Press embedded-bracket fixture, input fixture input
hole of ceiling until wholly entering. Unwrap the three
fixtures, tighten screw, and confirm that embedded-
bracket has already been fixed on ceiling.
Notes: embedded-bracket and ceiling must link
with steel belt so as to avoid dome dropping. The steel
belt should be offered by customer.
Step 4: connect to mechanical module wiring
Power line
Video line
Control line
Step 2: fix ceiling-mount bracket
Insert anchor-screws to 3 holes and fasten them
with pad & nut.
- 5 -
Connect video cable,
power line and control line with
mechanical module. As picture
directing.