CEP HT63 E Manuel de l'utilisateur - Page 18

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} CEP HT63 E. CEP HT63 E 20 pages.

 The HT63-E Terminal must not be installed or located where the surface temperature of the plastic
case may exceed 85°C.
 All cables connected to the HT63-E Terminal must be secured or clamped, immediately adjacent to
the modem's connectors, to provide strain relief and to avoid transmitting excessive vibration to the
modem in the installation.
 Ensure the cables, supplying power, audio headset, and input cable to the HT63-E Terminal, does
not exceed 3 metres.
 To protect power supply cables and meet the fire safety requirements when the unit is powered
from a battery or a high current supply, connect a fast 1.25A fuse in line with the positive supply.
 Do not connect any incompatible component or product to the HT63-E Terminal.
CEP AG may refuse warranty claims where evidence of product misuse is found.

4.3 SIM card precautions

Before handling the SIM card in your application, ensure that you are not charged with static
electricity. Use proper precautions to avoid electrostatic discharges.
When the SIM card hatch is opened, the SIM card connectors lie exposed under the SIM card
holder.
Caution! Do not touch these connectors! If you do, you may release an electrical discharge
that could damage the modem or the SIM card.
When designing your application, the SIM card's accessibility should be taken into account. We
always recommend that you have the SIM card protected by a PIN code. This will ensure that
the SIM card cannot be used by an unauthorized person.

4.4 Antenna precautions

If the antenna is to be mounted outside, consider the risk of lightning. Follow the instructions
provided by the antenna manufacturer.
 Never connect more than one modem to a single antenna. The modem can be damaged by radio
frequency energy from the transmitter of another modem.
 Like any mobile station, the antenna of the modem emits radio frequency energy. To avoid EMI
(electromagnetic interference), you must determine whether the application itself, or equipment in
the application's proximity, needs further protection against radio emission and the disturbances it
might cause. Protection is secured either by shielding the surrounding electronics or by moving the
antenna away from the electronics and the external signals cable.
 The modem and antenna may be damaged if either come into contact with ground potentials other
than the one in your application. Beware, ground potential are not always what they appear to be.