CAUTION
For installation
when
the dishwasher
is to be left unused
in freezing
temperature:
Turn off electrical
power and shut off water supply
at the
hand valve, Remove lower panel. Disconnect
both inlet and outlet
lines at
the DRAIN
valve. This permits water to drain from the dishwasher
tank,
pump and drain line. Disconnect
both the inlet and outlet
lines at the
FILL
valve. Make provisions
to control
water drained from unit. Reinstall
lower panel. Turn on electrical
power.
On Custom and Imperial
models, close door and latch handle. Turn Cycle
Selection
Dial until
it clicks in "Rinse
& Hold"
position.
Push "Rinse
&
Hold"
button
and allow machine
to run until
it turns off. Turn off elec-
tricity.
On Patrician
and Superba
models,
close door
and latch
handle.
Push
"Rinse
& Hold"
button.
Allow
machine
to run four or five minutes.
Push
"Cancel
Cycle"
button
and wait for machine
to turn off. Turn off elec-
tricity.
To complete
installation
later:
Remove lower panel.
Connect drain and fill valves (both inlet and outlet).
Reinstall
lower panel.
Turn on water and electrical
supplies.
DETAILS AND CONNECTIONS
KITCHENAID
DIVISION
FORM
13651A
(2-81)
(Supsds.
F. 13651)
TROY,
OHIO
45374
PAINTED