Avantco 178Z2FWMS Manuel d'entretien - Page 9

Parcourez en ligne ou téléchargez le pdf Manuel d'entretien pour {nom_de_la_catégorie} Avantco 178Z2FWMS. Avantco 178Z2FWMS 18 pages. Commercial top mount reach-in freezer, solid door
Également pour Avantco 178Z2FWMS : Manuel de l'utilisateur (9 pages)

Avantco 178Z2FWMS Manuel d'entretien
Temperature Controller Settings
Code
/5
/6
Ad
Add
AHA
ALA
d6
d8
dl
dP1
dt1
Description
Unit of measure
Display decimal point
Timed delay for high &
low temperature alarm
High temperature alarm
bypass via door open
High temperature alarm
Low temperature alarm
Display during defrost
High temperature alarm
bypass after defrost
Defrost intervals
Maximum defrost length
Defrost end temperature
Service Manual
Options
°C or °F
Visible or Not Visible
0 to 240 minutes
1 to 240 minutes
-148°F to 999°F
-148°F to 999°F
0 = Temperature alternat-
ing with "dEF"
1 = last temperature before
defrost
2 = 'dEF'
1 to 240 hours
0 to 240 hours
1 to 240 minutes
58°F to 122°F
P. 9
Defaults
°F
Visible
60 minutes
15 minutes
18°F
-14°F
1
1 hour
6 hours
40 minutes
50°F