CORNING Centrix Manuel d'instructions - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel d'instructions pour {nom_de_la_catégorie} CORNING Centrix. CORNING Centrix 8 pages. System splitter/cwdm cassette installation
Également pour CORNING Centrix : Routage des cavaliers (20 pages), Manuel de démarrage rapide (2 pages)

CORNING Centrix Manuel d'instructions
7.

Connector Care and Cleaning

WARNING: Never look directly into the end of a fiber that may be carrying laser light. Laser light can
be invisible and can damage your eyes. Viewing it directly does not cause pain. The iris of the eye will
not close involuntarily as when viewing a bright light. Consequently, serious damage to the retina
of the eye is possible. Should accidental eye exposure to laser light be suspected, arrange for an eye
examination immediately.
WARNING: Isopropyl alcohol is flammable with a flashpoint at 54°F. It can cause irritation to eyes on
contact. In case of contact, flush eyes with water for at least 15 minutes. Inhalation of vapors irritates
the respiratory tract. Exposure to high concentrations has a narcotic effect, producing symptoms of
dizziness, drowsiness, headache, staggering, unconsciousness, and possibly death.
• Always keep dust caps on connectors and adapters when not in use.
• Ensure dust caps are clean before reuse.
• Use optical cleaning materials as standardized by your company.
• Clean the connector before every mating, especially for test equipment patch cords (jumpers).
• A minimum level of cleaning is listed below. Local procedures may require more rigorous cleaning
methods.
Step 1:
Remove plugs from the connector adapter.
Step 2:
Wipe the connector ferrule twice with a lint-free wiping material moistened with isopropyl alcohol.
Then wipe across the end of the ferrule.
Step 3:
Repeat previous step with a dry wipe.
Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA
800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/opcomm
Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products without
prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are
the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2016-2017 Corning Optical Communications. All rights reserved.
Standard Recommended Procedure 003-1017-AEN | Issue 2 | April 2017 | Page 8 of 8