CORNING ONE GX Manuel d'information générale - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel d'information générale pour {nom_de_la_catégorie} CORNING ONE GX. CORNING ONE GX 12 pages. Higher power 40 w dual-band wcs/2.5 ghz tdd das remote
Également pour CORNING ONE GX : Fiche d'installation rapide (14 pages)

3.
REQUIRED HEADEND CONNECTIONS FOR
DEPLOYMENTS WITH CORNING® OPTICAL
NETWORK EVOLUTION (ONE™) SOLUTION
(CONTINUED)
Step 5:
Connect a pair of QMA/QMA cables from each
of the service group UL and DL output ports
to the OCH optical module UL and DL link
ports. IFB supports connections to two optical
modules per service group (see Figure 3).
Note the following:
• The IFB output connections to the OCH are
performed using QMA/QMA cables (not
provided with unit). Corning accessory kits,
including appropriate cables, can be ordered
separately.
• Each IFB supports connections to two optical
modules (i.e., one OCH-8 or two OCH-4 units)
per service group so that each unit supports
connections to up to six OCH-4/three OCH-8
units.
Step 6:
Refer to Figure 4 and perform the
management connections as follows:
1. Connect the SC-450 front panel "LAN" port
2. Connect the OCH "To SC-450" port to one
Corning Optical Communications
to any one of the HEU control module's
(HCM/ACM) four "INTERNAL" ports using an
RJ45 CAT 5 Ethernet cable (provided with
the SC-450). See Figure 4.
of the SC-450 RJ45 ports using an RJ45
CAT 5 Ethernet cable. See Figure 5.
Figure 3. IFB-to-OCH Connections
Figure 4. HCM-to SC-450 Management Connection
Figure 5. OCH-to-SC-450 Management Connection
Quick Installation Sheet | CMA-600-AEN | Page 5