Step 3:
Slide the splice protector over the splice. Splice per manufacturer's instructions.
Step 4: Carefully route the fibers back into the tray and place the protected splice into the organizer.
Step 5:
Repeat until all fibers are spliced. Each fiber must be spliced consecutively.
Step 6: Make sure all fibers are below the fiber retaining tabs. Align the hole in the cover with the hole in the
tray. Snap the cover onto the tray (Figure 12).
11.
Using the Step-Slot Splice Organizer
Step 1:
Spliced fibers in the OSE-ST-2 splice tray are stored in the
step-slot organizer. This organizer accepts 250 and 900 µm
fibers (Figure 13). The 250 µm fibers are secured in the lower
grooves in the organizer while the 900 µm fibers fit into the
surface slots.
Step 2:
When splicing 250 µm fibers, protect the splices using the
Crimp & Go
splice protectors provided with the OSE-ST-2
®
splice tray. Refer to the splicing documentation, if necessary,
for detailed instructions on the use of these protectors.
a. Place the splice protector over the splice point with the opening in the Crimp & Go® splice
protector facing down towards the organizer.
b. Squeeze the protector closed and insert into the organizer.
IMPORTANT:
Avoid twisting the fiber as you insert it into the organizer.
• If using Crimp & Go splice protectors with 250 µm fiber, do not use the RTV silicone compound
(RTV).
• If splicing 900 µm fiber, do not use Crimp & Go splice protectors.
• RTV can be used on 250 µm fibers, however, Crimp & Go splice protectors are the preferred
method.
Step 3:
When splicing 900 µm fibers, protect the
fibers using RTV.
a. Place the splices in the organizer in
consecutive order.
b. Fill the slots holding splices with
RTV as shown in Figure 14. Do not
overfill and avoid the empty slots.
c.
Place a piece of waxed paper, cut
to size, over the RTV to prevent the
RTV from sticking to the tray cover.
900 µm
TPA-4957
Standard Recommended Procedure 001-285 | Issue 4 | February 2017 | Page 7 of 8
250 µm
Figure 13
Figure 14