TROUBLESHOOTING
Any trouble occurring might be due to a minor problem that you can correct yourself following
the instructions below. Do not try any further action if the pointers given cannot solve the
problem!
Repairs on the cabinet must be made only by a qualified refrigeration engineer. Incompetent
repair work can cause serious personal danger: contact your service organisation for any
repairs needed.
Cabinet does not work (no audible running noise or only fan noise audible
Possible Cause:
a) automatic evaporator defrosting active or
thermostat switched off
b) power plug not connected
c) fuse blown, power plug or socket defective
d) condenser fins dirty
Storage Temperatuere too high
a) automatic defrosting active
b) ambient temperature too high or
c) distance to wall not adhered
c) lack of air intake due to
obstruction of grill
d) condenser fins dirty
Storage Temperature too low
a) misadjustment
Cabinet lighting failed
a) lighting not switched on
b) the starter or light fitting is defective
Heavy Condensation in Display Area
Extreme ambient temperature – relative humidity
is more than 60% or very high summer temps
Water under or in front of cabinet
a) automatic defrosting defective
b)extreme operating environment. Relative
humidity over 60% or high summer temperatures
causes overflow of drip tray
Formation of Odour in Cabinet
a) Spaces under return air grill dirty
b) Drain pipe blocked
c) Spillage
In the interest of continual product development we reserve the right to change any of the
details and specifications without notice.
None: cooling will automatically
switch on again
Insert plug properly. Switch ON
Contact your electrician or service
organisation
Contact service organisation for
maintenance
None: Temporary minor temperature
rise during defrosting is normal
Avoid extreme operating
`
environment i.e temperature over 25°
Adjust storage temperature-controller
Maintain presribed minimum distance
Remove any obstacles in air intake
area
Contact engineer to perform
maintenance
Adjust storage temperature in small
increments
Switch lighting on
Replace starter or complete fitting
Improve operating environment.
install air onditioning to reduce
room temperature to below 25° C
Wipe water off. If new water forms
within the next 48 hours contact your
service organisation
Clean
Remove blockage
Clean
Corrective Measure:
Page 16