James products SONIC 6MX Manuel de l'utilisateur - Page 10
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} James products SONIC 6MX. James products SONIC 6MX 16 pages.
5)
Setting the timer– When power is on, the timing setting figure will flash once the
option button has been pressed. This indicates that a time setting is required. To set the
timer, press the
The ultrasonic's cleaning function will instantly start once the
The LCD display window displays "U" which represents that the ultrasonic is working.
Cleaning will stop automatically when the cleaning time (seconds) and (minutes)
has counted down to "00" on both sides. The figure will resume the original setting
automatically. This is the "memory function".
6)
Memory Function and Pause Function
is touched; the memory function will be activated to keep the "MIN" figure in the memory
(but not the "SEC"). When the timer stops automatically, the memorized "MIN" figure will
be remembered. It is convenient for frequent users who repeat with same cleaning time
cycle, as there is no need to reset again and again. The Green Button is also a PAUSE
function button allowing you to pause the unit whilst the ultrasonic timer is still running,
touch
again to release the pause and continue the operation ( need to RESET
desired memorized setting figure again after Pause function is used).
7)
Use of degassing function: at the normal working state, the machine will start degassing
function once the
will stop once
8)
Red Button- This is the power switch for the machine. When you have finished using
the machine, touch
the unit from the mains supply and remove the power cable.
8
button to set the required cleaning time (Minutes).
button is pressed. Then, the LCD displays "D". Degassing function
button is pressed again. Then, the LCD displays "U".
to make sure that all of the displays have turned off. Disconnect
(= Start/Pause). Every time the Green Button
button is pressed.