III. Technical Specifications
Model
Performance Condition: Air 26℃ ℃ ℃ ℃ , Water 26℃ ℃ ℃ ℃
Heating capacity
KW
C.O.P.
Performance Condition: Air 15℃ ℃ ℃ ℃ , Water 26℃ ℃ ℃ ℃
Heating capacity
KW
C.O.P.
Advised Water Flux
m³/h
Power supply
Rated power Kw
Rated current A
Water pipe in-out
spec
mm
Water pipe in-out
spec(For UK) mm
Net weight / Gross
weight
Kg
Notice:
1-
This Heat Pump can work well between 0℃~+43℃ air temperature;
efficiency will not be guaranteed out of this range. Please take into
consideration that the pool heater performances may vary under different
conditions. Consult your Pool specialist.
2-
We reserve the right to make improvements periodically without further
notice. For details please refer to the cover-plate on the Heat Pump.
GP00
GP01
GP02
3.6
5
5.2
5.3
6.3
2.7
3.7
4.1
4.3
4.5
2.5
3
3-4
0.66
0.86
1.11
3
3.9
5.0
31/36
35/40
45/50
GP03
GP04
7
10
13
6.2
6.3
5
7
9
4.4
4.5
4-6
5-7
220-240V/1Ph/50Hz
1.59
2
7.2
9.1
50
48
52/57
66/70
GP05
GP06
17
25
6.2
6.4
12
16.5
4.5
4.5
6.5-8.5
8-10
380-415V/3
2.67
3.67
12.1
16.7
85/93
127/137
GP07
26
6.5
17
4.7
8-10
Ph/50Hz
3.62
5.5
127/137