Garden PAC InverTech GHD-150-0227 Manuel d'installation et d'utilisation - Page 18

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Garden PAC InverTech GHD-150-0227. Garden PAC InverTech GHD-150-0227 20 pages.

Garden PAC InverTech GHD-150-0227 Manuel d'installation et d'utilisation
For water pump: Voltage 400V
Power Supply
400V~/50Hz
Earthing
Power Supply
400V~/50Hz
Parallel connection with filtration clock
Note: The installer should connect A parallel with B (as above picture). To start the water
pump, condition A or B is connected. To stop the water pump, both A and B should
be disconnected.
Breaker/fuse
(Customer prepare)
Breaker/fuse
(Customer prepare)
Earthing
A: Water pump timer
B: Water pump wiring of Heat Pump
For installers and professionals
Power Cord
Water Pump
Contactor
coil voltage: 400V
- 16 -
Water Pump