Wet Area Installations

For wet area lighting within 10 feet (3M) of a pool or spa, the luminaire
shall be installed in areas not subject to incidental contact from people, pets,
vehicles, and foot traffic, except when the luminaire is adequately guarded.
Section 4.
The Jandy Infinite WaterColors Nicheless LED Light is designed
to be powered and operated with the Jandy Infinite WaterColors
LED Light Controller, the lights will not operate when powered
from an alternate transformer. Follow all installation and operating
instructions that accompany this product, as well as the Jandy
Infinite WaterColors LED Light Controller (Model: IWCLC300W).
NOTE: Always consider the cable length when calculating the input
voltage at the transformer. The maximum run of service between
transformer and lights should not exceed 200ft. in length, inclusive
of the use of a J Box or not.
To the extent allowed by local installation codes in effect in the installation
jurisdiction and capacity of the electrical equipment, multiple Jandy lights
may be controlled with a Infinite WaterColors LED Light Controller.
4.1
Wiring to an AquaLink
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION,
which could result in serious injury or death.
Fault Circuit Interrupter (GFCI, in Canada: Class A type) for 120
Volt transformers should be used if required by the transformer
manufacturer or if required by the local applicable code and/or
Authority Having Jurisdiction (AHJ). When a GFCI is used, the
conductors on the load side of the GFCI circuit shall not occupy
conduit, boxes, or enclosures containing other conductors unless the
additional conductors are also protected by a GFCI. Test the GFCI
on a routine basis. Refer to local codes for complete details.
Page 10
Jandy
Infinite WaterColors
®
Controller Wiring Options
WARNING
Nicheless LED Light | Owner's Manual
RS Control System
®
A Ground