Gardena 19080 Manuel d'utilisation - Page 10

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Gardena 19080. Gardena 19080 18 pages. Smart automatic home & garden pump
Également pour Gardena 19080 : Manuel de l'opérateur (9 pages)

Gardena 19080 Manuel d'utilisation
ß
Error­LED
:
L1
Reset
L1
L2
Problem
Error­LED flashes 1 time.
During the initial operation, the
pump did not suck water for
30 seconds.
Pump does not suck water
Pump does not start
Flow Sensor signal is faulty
In the case of an error, the Error-LED
disturbance states through various flashing frequencies, each with
a 2 second break.
Error­LED
L3
flashes 1 time
Error­LED
flashes 2 times
Error­LED
flashes 3 times
Error­LED
flashes 4 times
To delete the Error Indicator disconnect the pump from the mains.
Possible Cause
Pump was not sufficiently filled
with liquid to be pumped.
Air cannot escape on the pressure
side, because the pressure side
outlets are closed.
The pump housing has heated
up and the thermal circuit breaker
has been activated.
Pump is blocked.
Flow Sensor is blocked.
ß
shows the corresponding
L1
Problem with the initial operation
(In case of an error, LED
after the Pump starts.
Problem with the initial operation
(In case of an error, LED
after the Pump starts.
Problem during the current operation.
In case of an error, the fault LED
30 seconds after the water has failed to appear.
Problem during the current operation.
ß
The fault LED
begins to flash 60 minutes or
L1
two minutes after the occurrence of the fault.
Remedy
v Fill the pump and make sure
that water does not drain out
on the pressure side during
the suctioning process
(see 4. OPERATION).
v Open the pressure side out-
lets (see 4. OPERATION).
1. Open possible shut-off
device in the pressure line
(release pressure).
2. Ensure sufficient ventilation
and let the pump cool down
for 20 min.
3. Start the pump
(see 4. OPERATION).
1. Manually remove the blockage
(see To loosen the impeller).
2. Let the pump cool down for
20 min.
v Clean the flow sensor
(see To clean the flow sensor).
ß
flashes 30 seconds
L1
ß
flashes 6 minutes
L1
ß
flashes for
L1
23