Gardena 2000/2 Clear 18V P4A Manuel de l'opérateur - Page 10

Parcourez en ligne ou téléchargez le pdf Manuel de l'opérateur pour {nom_de_la_catégorie} Gardena 2000/2 Clear 18V P4A. Gardena 2000/2 Clear 18V P4A 18 pages. Battery submersible pump/battery rain water tank pump

Gardena 2000/2 Clear 18V P4A Manuel de l'opérateur

6. TROUBLESHOOTING

DANGER! Risk of injury!
Injury when the product starts accidentally.
v Remove the battery before you troubleshoot the
product.
Problem
Pump is running,
but doesn't deliver
Pump is running but the delivery
drops suddenly
Pump does not start or stops.
(L1)
LED
is flashing green [ Fig. O4 ]
Pump does not start or stops.
(Wp)
Error-LED
is illuminated red
[ Fig. O4 ]
Pump does not start or stops.
(Wp)
Error-LED
is flashing red
[ Fig. O4 ]
Pump does not start or stops.
(Wp)
Error-LED
is not illuminated
[ Fig. O4 ]
Charging is not possible.
Battery charge indicator
is continuously illuminated
[ Fig. O3 ]
20
Possible Cause
Air cannot escape, because
the pressure line is closed.
(Possible kink in the pressure hose.)
Air in suction foot.
Foot / Filter is clogged.
Water level below minimum water
level when put into operation.
Foot / Filter is clogged.
Battery is empty.
Battery temperature is outside the
permissible temperature range.
Dry-running protection has tripped.
Overtemperature of the control panel. v Let the control panel cool down
Air is in the hose.
Water has entered the battery.
There are drops of water or moisture
between the battery contacts in the
battery container.
Motor is blocked.
Product is defective.
Battery is not put completely into
the battery holder.
Battery is defective.
Product is defective.
The battery is not connected
(Lc)
(correctly).
Battery contacts are dirty.
Remedy
v Open the pressure line (e. g. shut-off
valve, delivery units).
v Wait for about max. 60 seconds until
the pump has vented; if necessary,
switch off / on several times if neces-
sary. If this does not help briefly start
the pump in the water once without
the hose.
v Clean the foot / filter.
v Submerge the pump deeper.
v Clean the foot / filter.
v Charge the battery.
v Wait until the battery temperature is
between 0 °C – + 45 °C again.
v Submerge the pump deeper.
(e. g. remove it from the sun).
v Start the pump once briefly in water
without a hose.
v Allow the battery to dry in a pro-
tected place.
v Remove the water drops / moisture
with a dry cloth.
v Contact the GARDENA Service.
v Contact the GARDENA Service.
v Put the battery completely into
the battery holder until it audibly
engages.
v Replace the battery.
v Contact the GARDENA Service.
v Connect the battery to charger
correctly.
v Clean the battery contacts (e. g. by
connecting and disconnecting the
battery several times. Replace the
battery if necessary.