Gardena 6000/5 inox automatic Manuel d'utilisation - Page 4

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Gardena 6000/5 inox automatic. Gardena 6000/5 inox automatic 9 pages. Deep well pump
Également pour Gardena 6000/5 inox automatic : Manuel d'utilisation (9 pages), Manuel d'utilisation (17 pages), Manuel d'utilisation (9 pages), Manuel d'utilisation (9 pages), Manuel de l'opérateur (9 pages), Manuel d'utilisation (10 pages)

Gardena 6000/5 inox automatic Manuel d'utilisation

5. Putting into Storage

Storage:
The storage location must not be accessible to children.
v Store the pump away from frost before the first frost sets in.
Disposal:
The product must not be added to normal household waste.
(in accordance with
It must be disposed of in line with local environmental regulations.
RL2002/96/EC)

6. Maintenance

Clean priming area:
0
1. Unscrew both screws
2. Clean priming area of the pump and inlet filter
3. Fix inlet filter
with the two screws
For safety reasons, a damaged turbine must only be
!
replaced by GARDENA Service.

7. Trouble-Shooting

Unblock non-return valve:
A blockage of the non-return valve
a bent wire hook. The non-return valve
5
move freely for the pump to work.
1. Unscrew pressure hose
#
2. Insert bent wire hook
3. Pull bent wire hook
moves freely.
"
4. Screw pressure hose
12
DANGER! Electric shock!
There is a risk of injury from electric
shocks.
V Disconnect the Deep Well Pump from the mains
power supply before carrying out maintenance.
0
q
and remove the inlet filter
q
.
q
around the priming area again and screw tight
0
.
DANGER! Electric shock!
There is a risk of injury from electric
shocks.
V Before eliminating faults, disconnect the Deep
Well Pump from the mains power supply.
w
can be cleared with
w
must be able to
5
.
e
into blocked non-return valve
e
upwards until the non-return valve
5
on again.
Fault
Pump is running,
but doesn't deliver.
Pump doesn't start or
suddenly stops during
operation.
.
Pump runs, but output
suddenly decreases.
For any other malfunctions please contact the GARDENA service department.
Repairs must only be carried out by GARDENA service departments or specialist
dealers authorised by GARDENA.

8. Available accessories

GARDENA Fitting
GARDENA
Pump Connection Set
GARDENA
Dry-Running Safety *
GARDENA Electronic
Manometric Switch *
* GARDENA Dry Running Safety / Electronic Manometric Switch must not be installed directly on the pump,
as they must not be submerged in the water.
w
.
Possible cause
Remedy
Air cannot escape as the
v Open pressure line
pressure line is closed.
(e. g. bent pressure hose).
Priming area blocked.
v Disconnect mains plug
and clean priming area
(see 6. Maintenance).
When starting the pump,
v Immerse pump deeper
water height falls below the
(observe minimum water
min. water level.
level: see 9. Technical Data).
Non-return valve blocked.
v Unblock non-return valve.
Thermal protection switch
v Disconnect mains plug
switched pump off due to
and clean priming area
overheating.
(see 6. Maintenance).
Observe max. media
temperature (35 °C).
Power supply interrupted.
v Check fuses and electrical
plug-in connections.
Dirt particles are trapped in
v Disconnect mains plug
priming area.
and clean priming area
(see 6. Maintenance).
Priming area blocked.
v Disconnect mains plug
and clean priming area
(see 6. Maintenance).
For optimum utilisation of the pumping
capacity of the pump.
If the hose connection is to be detached
frequently.
Deactivates the pump automatically if
the pumped medium fails to flow.
With Dry-Running Safety. Ideal for converting
a pump into a pressure tank unit.
Art. 1723 / 1724
Art. 1752
Art. 1741
Art. 1739
13