KitchenAid KHTU165RSS0 Instructions d'installation et manuel d'utilisation et d'entretien - Page 3
Parcourez en ligne ou téléchargez le pdf Instructions d'installation et manuel d'utilisation et d'entretien pour {nom_de_la_catégorie} KitchenAid KHTU165RSS0. KitchenAid KHTU165RSS0 20 pages. Khtu100/khtu160 series 30" (76.2 cm) and 36" (91.4 cm) traditional series vented and non vented range hoods
Également pour KitchenAid KHTU165RSS0 : Liste des pièces (3 pages)
For vented models:
Do not terminate
the vent system
in an attic or other enclosed area.
Do not use 4" (10.2 cm) laundry-
type wall caps.
Use metal vent only. Rigid metal
vent is recommended.
Do not use
plastic or metal foil vent.
Fle×ible vent is not
recommended.
Flexible vent
creates back pressure that greatly
reduces the hood's performance.
• The size of the vent should be
uniform.
• Use no more than three 90 °
elbows.
Make sure there is a minimum
of 24" (61 cm) of straight
vent
between the elbows if more
than one elbow is used.
Do Not install two elbows
together.
The length of vent system and
number
of elbows should be
kept to a minimum
to provide
efficient
performance.
The vent system must have a
damper. If roof or wall cap has
a damper, Do Not use damper
supplied
with the range hood.
Use duct tape to seal all joints
in the vent system.
• Use caulking to seal exterior wall
or roof opening around the cap.
Note: It is recommended
that the
vent system be installed
before
installing
the hood.
Vent system needed for
installation is not included. 3-1/4" x
10" (8.3 cmx 25 cm) rectangular is
recommendecL _
vent through
I
I I
the roof
Roof venting
3-1/4"
x
(8.3 cmx 25 cm
vent through
the wall
Wall venting
wall
cap
Recommended
vent system
length
Use 3 1/4" x 10" (8.3 cm x 25 cm)
vent with maximum
length of
26 feet (8 m) for vent system.
For
best performance,
use no more
than three 90 ° elbows.To
calculate
the length of system you need,
add the equivalent
feet (meters)
for each vent piece used in the
system. See the following
example.
3-1/4" x 10" (8.3 cmx
25 cm}
vent system
3-1/4"
x 10"
wall
(8.3 crn x 25 cm)
90 ° elbow
cap
_-
6 ft. (1.8m)-_ll
_
Maximum length
= 26 ft.
(8 m)
1 -90 ° elbow
= 5ft,
(1.5m)
9 ft. (2.8 m) straight
= 9 ft. (2.8 m)
1 -wallcap
= 0ft.
(0m)
Length of 3-1/4" x 10"
(8.3 cmx 25 cm)
system
= 14 ft. (4.3 m)
Recommended
standard
fittings
3-1/4" x 16"
(8.3 cmx 25 cm)
90° elbow
= 5 ft. (1.5 m)
3-1/4" x 10"
(8.3 cmx 25 cm)
flat elbow
= 12 ft. (3,7 m)
3-1/4" x 10"
(8.3 cmx 25 cm}
wall cap
= Oft.(O m)
Note: Underside of hood must be a minimum of
24" (61 cm} from cooking surface.
4-3/4"
(12.1 cm}
3-3116"
(8.1 cm}
1-9/16"
(4.0 cm)
2-11/32"
13-3/8"
7-3/4"
(6.0 cm}
1-3/4"
(4.4 cm}
5-1/16"
Do not
(12.9 cm)
_
use these
9-27/32" _"i
knockouts
cm}
I
1-3/16"
3811 (76.2 cm)
17-3/4"
(3.0 cm}
_36
191.4
cm)
(45.1cm, 1
Roof-vented model shown.