Tools and Parts
Gather the required tools and parts before starting
installation. Read and follow the instructions provided
with any tools listed here.
Tools needed:
Level
■
Drill with 1
/
" (3.0 cm),
1
■
4
drill bits
Pencil
■
Wire stripper or utility knife
■
Tape measure or ruler
■
Pliers
■
Caulking gun and weatherproof caulking compound
■
Vent clamps
■
Jigsaw or keyhole saw
■
Flat-blade screwdriver
■
Metal snips
■
Phillips screwdriver
■
Metric hex key set
■
Parts needed:
Home power supply cable
■
/
" (12.7 mm) UL Listed or CSA Approved strain relief
1
■
2
3 UL Listed wire connectors
■
For vented installations, you will also need:
1 wall or roof cap
■
Metal vent system
■
For non-vented (recirculating) installations, you will also
need:
Recirculation Kit Part Number W1027063 for non-vented
■
(recirculating) installations only. See the "Assistance or
Service" section to order.
Charcoal Filter Kit part number W1027068 for non-vented
■
(recirculating) installations only. See the "Assistance or
Service" section to order.
6" (15.2 cm) diameter round metal vent duct - length required
■
is determined by ceiling height.
4
INSTALLATION REQUIREMENTS
/
" (9.5 mm), and
/
" (7.9 mm)
3
5
8
16
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs
■
installed
Vent transition with back draft dampers installed
■
Metal grease filter(s)
■
Vent cover support bracket
■
Mounting template
■
2-piece vent cover
■
4 - 3.5 x 9.5 mm screws
■
4 - 3.5 x 6.5 mm screws
■
2 - 2.9 x 6.5 mm screws
■
6 - 5 x 45 mm mounting screws
■
2 - 8 x 40 mm wall anchors
■
4 - 10 x 60 mm wall anchors
■
4 - 5.4 x 75 mm screws (for 10 x 60 mm wall anchors)
■
Torx
T20
adapter
®†
®†
■
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/
rating plate is located inside the range hood on the rear wall
of the range hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
This range hood is recommended for use with cooktops with a
maximum total rating of 65,000 BTUs or less.
Grounded electrical outlet is required. See the "Electrical
Requirements" section.
The canopy hood is factory set for venting through the roof
or wall. For non-vented (recirculating) Installation, see "For
Non-vented (recirculating) Installations Only" in the "Connect
Vent System" section. The Recirculation Kit Part Number is
W1027063. Charcoal filters are also required for non-vented
(recirculating) installations. The Charcoal Filter Kit Part Number is
W1027068. See the "Assistance or Service" section to order.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations:
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when
such standard is not applicable, the standard for Manufactured
Home Installation 1982 (Manufactured Home Sites, Communities
and Setups) ANSI A225.1/NFPA 501A or latest edition, or with
local codes.
†