Gardena 4000/5 Manuel d'utilisation - Page 6

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Gardena 4000/5. Gardena 4000/5 17 pages. Garden pump
Également pour Gardena 4000/5 : Manuel d'utilisation (10 pages), Manuel d'utilisation (17 pages), Manuel d'utilisation (12 pages), Manuel de l'opérateur (14 pages), Manuel de l'opérateur (11 pages), Manuel de l'opérateur (10 pages), Manuel d'utilisation (18 pages), Manuel de l'opérateur (10 pages), Manuel d'utilisation (19 pages), Manuel d'utilisation (13 pages)

Gardena 4000/5 Manuel d'utilisation
5
1
Special mode:
safe-pump-function:
6. Switching on pump 5000/5; 6000/6 inox:
Lift and hold the delivery hose
m vertically above the pump, insert the
power plug, press the On/Off button
(the LED shines green) and wait until the
pump has primed.
If the pump does not deliver within
min.
approx. 20 seconds, the LED flashes
1 m
orange.
If the pump does not deliver: 5000/5
within approx. 5 minutes / 6000/6 inox
within approx. 6 minutes, the LED shines
red and the pump switches off auto-
matically (see "7. Trouble- Shooting").
v If the pump does not automatically
z
switch off then manually switch the
pump off and check the hose for
leaks.
The specified maximum self-priming suction height of 8 m is
reached only if the pump is filled via the filler neck
overflow and if, while doing so and during the self-priming, the
delivery hose
medium escaping from the pump via the delivery hose
Additional electrical switching devices (e. g. remote control sys-
tems, pressure switches) can be used only in the special mode.
Activating the special mode:
1. When switching on, press the On/Off button
During the first 5 seconds, the green LED is illuminated;
then the LED blinks for 3 seconds.
2. When the green LED illuminates again after 8 seconds,
let go of the On/Off button
Deactivating the special mode:
1. Plug the mains plug into an energised mains socket.
The pump starts of its own accord.
2. Press the On/Off button
3. When switching on, keep the On/Off button
8 seconds until the green LED no longer flashes.
The safe-pump function uses the LED status display to alert the
user that there is no water flow. In addition, it acts as Dry-Run-
ning Safety, guarding against pump damage if the delivery side
is closed too long (e.g. closed valves) or if the water supply fails
(e. g. empty cistern).
LED flashes green:
LED flashes orange:
LED shines red:
LED flashes red:
at least 1
5
is held up sufficiently high to prevent any flow
5
.
ß
8a
. The pump switches off.
ß
8a
Normal operation
No water flow for at least 20 seconds
No water flow for at least 5 minutes
(pump has switched off automatically)
Alarm! Pump was started 3 times within
20 min. without water flow. (Pump can
no longer be started for 5 min. to allow
cooling, after which the LED shines red)
LED
8a
ß
up to the
7
.
5
for 8 seconds.
8a
ß
depressed for
8a
ß
17