Gardena PowerJet 18V P4A Manuel de l'opérateur - Page 8
Parcourez en ligne ou téléchargez le pdf Manuel de l'opérateur pour {nom_de_la_catégorie} Gardena PowerJet 18V P4A. Gardena PowerJet 18V P4A 10 pages. Battery blower
Problem
Possible Cause
Blower does not start
Battery temperature is outside
or stops.
the permissible temperature
(Wp)
Error-LED
is illuminated
range.
red [ Fig. O4 ]
There are drops of water or
moisture between the battery
contacts on the blower.
Engine is blocked.
Battery was connected while
holding down the start lever.
Start lever is out of order.
Blower does not start
Product is defective.
or stops.
(Wp)
Error-LED
is flashing
red [ Fig. O4 ]
Blower does not start
Battery is not put completely
or stops.
into the battery holder.
(Wp)
Error-LED
is not
illuminated [ Fig. O4 ]
Battery is defective.
Product is defective.
Charging is not possible.
The battery is not connected
(Lc)
Battery charge indicator
(correctly).
is continuously illuminated
Battery contacts are dirty.
[ Fig. O3 ]
Battery temperature is out-
side the permissible charging
temperature range.
Battery is defective.
(Lc)
Battery charge indicator
Mains plug of the charger is
is not illuminated [ Fig. O3 ]
not (correctly) plugged in.
Socket outlet, mains cable or
charger is defective.
NOTE: For any other malfunctions please contact the GARDENA service depart-
ment. Repairs must only be done by GARDENA service departments or specialist
dealers approved by GARDENA.
7. TECHNICAL DATA
Battery Blower
Unit
Flow rate
m
/min.
3
Max. blow speed
km/h
Weight (without battery)
kg
Sound pressure level L
1)
dB (A)
pA
Uncertainty k
pA
Sound power level L
:
2)
WA
measured / guaranteed
dB (A)
Uncertainty k
WA
Hand / arm vibration a
1)
m/s
2
vhw
Uncertainty k
vhw
Measuring process complying with:
EN 50636-2-100
1)
NOTE: The stated vibration emission value has been measured according to
a standardised test procedure and can be used for comparison of one electric
power tool with another. It can also be used for preliminary evaluation of expo-
sure. The vibration emission value can vary during actual use of the electric power tool.
System Battery
Unit
PBA 18V 2.5Ah W-B
Battery voltage
V (DC)
Battery capacity
Ah
Number of cells (Li-Ion)
Appropriate POWER FOR ALL system Battery Chargers: AL 18..CV.
12
Remedy
v Wait until the battery
tem perature is between
0 °C – + 45 °C again.
v Remove the water drops /
moisture with a dry cloth.
v Remove the obstacle.
Start again.
v Release the start lever
and start again.
v Contact the GARDENA
Service.
v Contact the GARDENA
Service.
v Put the battery completely
into the battery holder until
it audibly engages.
v Replace the battery.
v Contact the GARDENA
Service.
v Connect the battery to
charger correctly.
v Clean the battery contacts
(e. g. by connecting and
disconnecting the battery
several times. Replace the
battery if necessary.
v Wait until the battery
tem perature is between
0 °C – + 45 °C again.
v Replace the battery.
v Insert the mains plug into the
mains socket (completely).
v Check the mains voltage.
Let the charger be checked
if necessary by an author-
ised specialist dealer or the
GARDENA Service.
Value (Art. 14890)
7.9
100
1.8
85
2.5
95 / 96
1
0.4
1.5
RL 2000/14/EG
2)
Value (Art. 14903)
18
2.5
5
Battery Charger
Unit
AL 1810 CV P4A
Mains voltage
V (AC)
Mains frequency
Hz
Rated power
W
Battery charging voltage
V (DC)
Max. battery-charging
mA
current
Battery charging time 80 % /
97 – 100 % (approx.)
PBA 18V 2.0Ah W-B
min.
PBA 18V 2.5Ah W-B
min.
PBA 18V 4.0Ah W-C
min.
Permitted charging
°C
temperature range
Weight according to
kg
EPTA-Procedure 01:2014
Protection class
Appropriate POWER FOR ALL system Batteries: PBA 18V.
8. ACCESSORIES
GARDENA System Battery
Battery for additional duration or for replacement.
PBA 18V/45 P4A
PBA 18V/72 P4A
GARDENA Battery Quick
Charger for fast charging the POWER FOR ALL
Charger AL 1830 CV P4A
system Batteries PBA 18V..W-..
9. SERVICE / WARRANTY
Service:
Please contact the address on the back page.
Warranty statement:
In the event of a warranty claim, no charge is levied to you for the services
provided.
GARDENA Manufacturing GmbH grants a warranty for all original
GARDENA new products for two years from the date of original purchase
from the retailer, provided that the devices have been for private use only.
This manufacturer's warranty does not apply to products acquired second
hand. This warranty includes all significant defects of the product that can
be proved to be material or manufacturing faults. This war ranty is fulfilled
by supplying a fully functional replacement product or by repairing the
faulty product sent to us free of charge; we reserve the right to choose
between these options. This service is subject to the following provisions:
• The product has been used for its intended purpose as per the recom-
mendations in the operating instructions.
• Neither the purchaser nor a third party has attempted to open or repair
the product.
• Only Original GARDENA replacement parts and wear parts have been
used for operation.
• Presentation of the receipt.
Normal wear and tear of parts and components (such as blades, blade
fixing parts, turbines, light bulbs, V-belts / toothed belts, impellers, air
filters, spark plugs), visual changes, wear parts and consumables are
excluded from the warranty.
This manufacturer's warranty is limited to replacement and repair of
products in accordance with the abovementioned conditions. The
manufacturer's warranty does not constitute an entitlement to lodge
other claims against us as a manufacturer, such as for damages.
This manufacturer's warranty does not, of course, affect statutory
and contractual warranty claims against the dealer / retailer.
The manufacturer's warranty is governed by the law of the Federal
Republic of Germany.
In case of a warranty claim, please return the faulty product, together with
a copy of the receipt and a description of the fault, with postage paid to
the service address.
Consumables:
The blower tube and the nozzle are consumables and are not included in
the warranty.
Value (Art. 14900)
220 – 240
50 – 60
26
18
1000
96 / 124
120 / 154
192 / 244
0 – 45
0.17
/ II
Art. 14903
Art. 14905
Art. 14901