6. TROUBLESHOOTING

Problem
Blower / vacuum does not start Battery is not put completely into
Blower / vacuum vibrates
abnormally
ç
Error-LED
on
the control panel
flashes
ç
¥
Error-LED
on the battery
flashes
ß
Wb
¥
Error-LED
on the battery
illuminates
Charging control lamp
charger does not illuminate
ß
ß
Wc
Lc
Charging control lamp
the charger flashes rapidly
(4 times per second)
Error-LED
on the charger
flashes
Error-LED
on the charger
illuminates
DANGER! Risk of injury!
Cut injury when the rotor blades turn or the product
starts accidentally.
v Remove the battery and wait for the rotor blades to stop
before you troubleshoot the product.
Possible Cause
the battery holder.
On LED is off.
Mechanical failure.
Over current, engine is blocked.
Blower tube, vacuum tube,
collection bag or intake cover is
not assembled correctly.
Abnormal speed.
Under voltage.
Battery temperature is out of
range.
Battery error / battery defective.
å
on the
Battery charger or charging cable
are not connected correctly.
å
on
Battery temperature is out of
range.
Battery error.
Temperature inside the charger
is too high.
Remedy
v Put the battery completely into
the battery holder until it audibly
engages.
v Push the On/Off button.
v Contact the GARDENA
Service.
v Remove the battery and remove
the obstacle.
v Assemble all parts until the
interlock audibly engage.
v If there is no blockage and the
parts are correctly assembled,
contact the GARDENA Service.
v Charge the battery.
v Use the battery in surroundings
where temperatures are
between – 10 °C and 40 °C.
v Contact the GARDENA Service.
v Connect the battery charger
and charging cable correctly.
v Use the battery in surroundings
where temperatures are
between – 10 °C and 40 °C.
v Remove the battery and
check that you use an original
GARDENA battery.
v Contact the GARDENA service.