b. Trouble Shooting
If the LCD Controller displays error codes when raising or lowering the desk, a reset
will be required.
1. Motor error (E01,E02 or E03,E04)
Control box can not detect motor halt plate signal or Control box detect one lifting
column is over loaded. This is a safety protection.
Pls take away any large loads from the desk top and reset the controller.
Should a reset fail to resolve the issue one or more motors will need to be
replaced.
2. Control box temperature protection (HOT)
This indicates that the control box temperature is above 75℃ or the system has
been in continuous use for 2min or more. The lifting columns are locked out for
up to 18mins as a safety precaution. For an urgent reset, unplug the power cord.
3. Asynchronous protection (E06)
Lifting columns are at different heights,more than 10mm, reset required.
4. Overload protection (E07)
Desk load in excess of 140kg, user needs to reduce load, then reset or just need
to wait for 3 seconds, it will recover.
5. Low Voltage protection (E08)
Power Voltage is too low for the controller, This is a safety cut out protection.
system will recover as soon as voltage returns to normal.
6. High Voltage protection (E09)
Power Voltage is too high for the controller, This is a safety cut out protection.
system will recover as soon as voltage returns to normal.
7. Control Box or Handset Issue (E10)
If Handset display E10 and will not disappear,control box or handset is broken.
c. Warranty Notice
1. This product must be used under the correct technical parameters.
2. Keep away from liquids, corrosives, gases and dusty environments.
3. Do not open any of the components, doing so will void any and all service
support and manufactures warranties.