Test and Flush
1. Make sure Cold water connector tap is turned off.
2. Turn water ON at mains or shut-off valve undersink.
3. Turn on Cold water connector tap and check for any leaks.
4. If a leak shows, repeat Step 7 points 1-3.
5. Now turn ON the vented faucet and check again for leaks.
6. Run filter for 5-10 minutes to flush.
7. Optional: You can adjust the flow rate also by adjusting the blue and white tap
at the bottom of the UltraStream (see next section).
Testing pH and Setting Flow
Testing pH
How to test the pH of your water.
1. Add 2-3 drops of this reagent to 30ml of water to be tested.
2. Mix well.
3. Compare the final colour of the solution to the enclosed colour chart to get your
reading (It's a good idea to use a white background).
4. pH Colour Readings pH<7 Acidic, pH=7 Neutral, pH>7 Alkaline.
Setting the Flow Rate
How to get the correct water flow rate from your UltraStream.
1. Turn your UltraStream on its side.
2. Locate the base plate with two holes and remove.
3. Locate the blue and white tap.
4. Full flow rate occurs when the blue and white tap is in line with incoming hose.
5. For best performance flow rate should be around litre per minute.
Easy way: For most installations all you need to do is to turn the blue and white
tap 45 degrees.
Harder way: Put a 1 litre container under the UltraStream spout. Use a clock
with a second hand and time 1 minute. The container should be full at the end
of 1 minute.
p12