AlkaZone BHL-2100 Manuel d'installation et d'utilisation - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} AlkaZone BHL-2100. AlkaZone BHL-2100 10 pages. Antioxidant water fountain /alkazone water ionizer

TOOLS NEEDED:
* Pliers or wrench
* Scissors or sharp knife
MACHINE INSTALLATION:
1. Position the water Fountain on a firm and level surface or mount on the wall away from any
extreme heat or direct sunlight or flame.
2. Install the diverter to the desire faucet
(a). Remove the screw cap (aerator) from the current faucet.
(b). Screw the diverter on the faucet carefully, then tighten with a pair of piers.
You may need a matching adapter for mounting diverter on to the faucet.
3. Plastic Hose installation
(a). Measure the length of hose from a faucet diverter to the Water Fountain. Make sure to leave
enough room to account for the swinging movement of the faucet or possible future relocation of
the system. Cut and prepare two pieces of hose with a sharp knife or scissors
(b). Connect a hose to the Water Fountain Inlet and to the faucet diverter Outlet using clamps.
(c). Connect the other hose to the Acid Outlet of the Water Fountain using a clamp and let it drain
freely into your sink, or a container if you want to use the acid water.
4. Connect the flexible metal hose to Alkaline Water Exit on the top of the water Fountain.
(a). Wet the end of the hose with water and firmly insert it while twisting the hose.
5. Plug in the power cord to a 120V electrical outlet.
6. Run the cold water through the Water Fountain for test operation and cleaning system.
7. Power will turn on and off automatically and be activated by water flow.
IN CASE OF CHANGING HIGH PERFORMANCE FILTER
1. Turn off water from faucet.
2. Remove the filter cover from the filter case by gently pushing up.
3. Turn the filter counter-clockwise and pull up to release from the base while holding the body with the
other hand.
4. Mount the new filter to the base by simply reversing the step 3 above..
5. Push the red button to reset the counter.
6. Reinstall the filter cover to the filter case.

Installation Instructions

5