Garmin GPSMAP 1222 TOUCH Manuel d'instructions d'installation - Page 4

Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} Garmin GPSMAP 1222 TOUCH. Garmin GPSMAP 1222 TOUCH 8 pages.

Garmin GPSMAP 1222 TOUCH Manuel d'instructions d'installation
The port labeled NMEA 2000 is used to connect the device to a
standard NMEA 2000 network.
Item
Description
NMEA 2000 compatible Garmin device
GPS antenna
Ignition or in-line switch
NMEA 2000 power cable
NMEA 2000 drop cable
12 Vdc power source
NMEA 2000 terminator or backbone cable
NMEA 2000 T-connector
NMEA 2000 terminator or backbone cable
J1939 Engine Network Connection Considerations
You must use a Garmin GPSMAP J1939 accessory cable when
connecting the chartplotter to the J1939 engine network to
prevent corrosion due to moisture. Using a different cable voids
your warranty.
If you have an existing engine network on your boat, it should
already be connected to power. Do not add any additional power
supply.
This chartplotter can connect to an engine network on your boat
to read data from compatible devices such as certain engines.
The engine network follows a standard and uses proprietary
messages.
You should connect only one chartplotter to one engine network.
Connecting more than one chartplotter to one engine network
may result in unexpected behavior.
The port labeled J1939 is used to connect the device to the
existing engine network. You must route the cable within 6 m
(20 ft.) of the engine network backbone.
The Garmin GPSMAP J1939 accessory cable requires
connection to a power source and proper termination. For more
information on connecting to your engine network, see the
manufacturer's engine documentation.
Pin
Wire Color
Bare
Red
4
NOTICE
Description
Shield
Power, positive
Pin
Wire Color
Black
White
Blue

NMEA 0183 Connection Considerations

• The chartplotter provides one Tx (transmit) port and one Rx
(receive) port.
• Each port has 2 wires, labeled A and B according to the
NMEA 0183 convention. The corresponding A and B wires of
each internal port should be connected to the A (+) and B (-)
wires of the NMEA 0183 device.
• You can connect one NMEA 0183 device to the Rx port to
input data to this chartplotter, and you can connect up to
three NMEA 0183 devices in parallel to the Tx port to receive
data output by this chartplotter.
• See the NMEA 0183 device installation instructions to identify
the transmit (Tx) and receive (Rx) wires.
• You must use 28 AWG, shielded, twisted-pair wiring for
extended runs of wire. Solder all connections and seal them
with heat-shrink tubing.
• Do not connect the NMEA 0183 data wires from this device
to power ground.
• The power cable from the chartplotter and the NMEA 0183
devices must be connected to a common power ground.
• The internal NMEA 0183 ports and communication protocols
are configured on the chartplotter. See the NMEA 0183
section of the chartplotter owner's manual for more
information.
• See the chartplotter owner's manual for a list of the approved
NMEA 0183 sentences that the chartplotter supports.
NMEA 0183 Connection Diagram
Item
Description
12 Vdc power source
Wiring harness
NMEA 0183 compliant device
Item Garmin Wire
Garmin Wire
Function
Color
Power
Red
Ground
Black
Tx (Out)
Blue
Rx (In)
Brown

Lamp and Horn Connections

The device can be used with a lamp, a horn, or both, to sound or
flash an alert when the chartplotter displays a message. This is
optional, and the alarm wire is not necessary for the device to
function normally. When connecting the device to a lamp or
horn, observe these considerations.
• The alarm circuit switches to a low-voltage state when the
alarm sounds.
• The maximum current is 100 mA, and a relay is needed to
limit the current from the chartplotter to 100 mA.
Description
Power, negative
CAN High
CAN Low
-
+
NMEA 0183 Device Wire
Function
Power
Data ground
Ground
Rx/A (In +)
Tx/A (Out +)