Garmin GNX Wind Manuel du propriétaire - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Garmin GNX Wind. Garmin GNX Wind 10 pages. Marine instrument
Également pour Garmin GNX Wind : Instructions d'installation (2 pages), Instructions d'installation (2 pages)

Garmin GNX Wind Manuel du propriétaire
5
Select an option:
• Press
to confirm the new value and return to the
SUBMENU category.
• Press
to cancel all changes and return to the
SUBMENU category.
The value in the selected category stops flashing.
6
Press
two times to return to the instrument screens.

Adjusting the Number of Instrument Screens

You can customize a maximum of four instrument screens.
1
From an instrument screen, press
2
Press
or
to select SYST, and press
3
Press
or
to select PGES, and press
4
Press
or
to select the number of instrument screens (1
through 4), and press
5
Press
two times to return to the instrument screens.

Customizing an Instrument Screen

You can customize the data shown in the three main areas of
each instrument screen.
1
From an instrument screen, press
instrument screen to customize.
2
Press
.
3
Press
to select DATA.
4
Press
or
to select an option:
• Select SUBMENU 1.1 to change the lower-left (speed)
value.
• Select SUBMENU 1.2 to change the upper-left (direction)
value.
• Select SUBMENU 1.3 to change the wind rose function.
5
Press
.
6
Press
or
to change the value.
7
Press
to confirm the change.
8
Repeat steps 4 through 7 for every value or function you
need to change on the current instrument screen.
9
Press
two times to return to the instrument screens.

Configuration Menus

This section provides details for the items in the configuration
menu, organized by menu and sub-menu decimal values.

1.0 DATA Configuration Settings

1.1 Upper data field configuration: Changes the wind direction
or angle type on the current instrument page.
1.2 Lower data field configuration: Changes the speed type
on the current instrument page.
1.3 Wind rose configuration: Changes the function of the wind
rose on the current instrument page.

2.0 FILT Configuration Settings

In the filter configuration menu, you can adjust damping of the
data received from the sensor before it is shown in each data
category (2.1 through 2.9).
The higher you set the update rate (0 through 9) for each data
category, more the data is dampened to remove the more
extreme readings. For example, setting a higher filter for TWS
may provide a more stable wind-speed reading in gusty
conditions.
The glossary defines the data-type abbreviations used in this
menu
(Abbreviation Glossary, page

3.0 UNIT Configuration Settings

3.1 WIND: Changes the units of measure used for wind speed.

Appendix

.
.
.
to confirm the setting.
or
to select an
3).
3.2 BSP: Changes the units of measure used for boat speed.

4.0 SENS Configuration Settings

4.1 ANGL: Adjusts the angle of the wind sensor to align with the
front of the boat.
4.2 RSSI: Shows the signal strength between the instrument
and the wireless wind sensor.
4.3 WXDR: Turns data from the connected wireless wind sensor
on or off. When off, data from the connected wireless wind
sensor is not transmitted over the NMEA 2000 network.
4.4 BSP%: Adjusts the calibration of boat speed information
shown on the instrument.
NOTE: This adjustment affects the information as shown on
the marine instrument only. Other devices using speed
information from the NMEA 2000 network must be calibrated
separately, if needed.

5.0 SYST Configuration Settings

5.1 LGHT: Adjusts the backlight level on a scale of 0 through
100%.
5.2 COLR: Sets the color of the instrument display.
Settings C00 through C06 are the custom colors available
locally on the marine instrument.
Setting C07 is a custom-color setting controlled by other
instruments on the NMEA 2000 network.
5.3 BEEP: Tuns the key-press sounds on or off.
5.4 POWR: Allows you to change how the instrument turns on.
The AuT option turns the instrument on automatically when
the NMEA 2000 network turns on.
The OFF option keeps the instrument off when the NMEA
2000 network turns on. The instrument must be turned on by
pressing .
5.5 PGES: Sets the number of instrument pages.
5.6 SCRL: Sets and adjusts your instrument screens to scroll
automatically. The value you set (0 through 9) represents the
number of seconds between each screen change.
A setting of 0 turns off scrolling.
5.7 DFLT: Restores the marine instrument to factory default
settings.
5.8 VRSN: Shows the installed software version.
Appendix

Abbreviation Glossary

This device uses abbreviations on many screens to indicate the
menu, setting, or type of data being shown.
ALOG: (Analog sub menu) The filter sub menu that adjusts the
dampening rate for wind data on the wind rose.
ANGL: (Angle sub menu) The sensor sub menu that adjusts the
wind-angle offset of the data from the wind sensor.
APP: (Apparent Wind Angle) Shown in the upper-left data field.
The wind angle measured relative to the bow of the vessel.
AWA: (Apparent Wind Angle) The wind angle measured relative
to the bow of the vessel.
AWS: (Apparent Wind Speed) The measured speed of the wind.
BEEP: (Beep sub menu) The system sub menu that enables
and disables key-press sounds.
BSP: (Boat Speed) The speed of the boat through the water.
BSP%: (Boat speed sub menu) The sensor sub menu that
adjusts the speed data shown from a connected speed
sensor.
BTW: (Bearing to Waypoint) The direction of travel towards a
destination waypoint.
3