Garmin GTX 327 Manuel du pilote - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel du pilote pour {nom_de_la_catégorie} Garmin GTX 327. Garmin GTX 327 8 pages. Mode a/c transponder
Également pour Garmin GTX 327 : Manuel du pilote (8 pages), Manuel du pilote (8 pages), Manuel du pilote (8 pages), Manuel du pilote (4 pages)

Garmin GTX 327 Manuel du pilote
Altitude Trend Indicator
When the 'PRESSURE ALT' page is displayed, an arrow may be displayed to the right of
the altitude, indicating that the altitude is increasing or decreasing. One of two sizes of arrows
may be displayed depending on the rate of climb/descent. The sensitivity of these arrows is set
using the GTX 327 Confi guration Mode vertical speed rate.
Timer Operation
To operate the Flight Timer:
1. Press the FUNC key until 'FLIGHT TIME' is displayed.
2. If the GTX 327 Flight Timer is confi gured as ACCUMULATE or CLEAR, the timer will begin
automatically when the unit senses that the aircraft has become airborne. The timer may
be reset to zero at every liftoff (CLEAR), continue accumulating time at liftoff (ACCUMU-
LATE) or may be controlled manually (MANUAL).
3. If desired, you may press START/STOP to pause or restart the timer.
4. Press CLR to reset the timer to zero.
5. If the timer is confi gured to start automatically it will pause when the Automated Airborne
Determination senses that the aircraft is on the ground.
To operate the Count Up timer:
1. Press the FUNC key until 'COUNT UP' is displayed.
2. If necessary, press CLR to reset the Count Up timer to zero.
3. Press START/STOP to count up.
4. Press START/STOP again to pause the timer.
5. Press CLR to reset the timer to zero.
To operate the Count Down timer:
1. Press the FUNC key until 'COUNT DOWN' is displayed.
2. Press CRSR and use the 0 - 9 keys to set the initial time. All digits must be entered (use
the 0 key to enter leading zeros).
3. Press START/STOP to count down.
4. Press START/STOP again to pause the timer.
5. When the Count Down timer expires, the 'COUNT DOWN' banner is replaced with a
fl ashing 'EXPIRED', and the time begins counting up.
6. Press CLR to reset the timer to the initial time value.
Automatic ALT/STBY Mode Switching
If the GTX 327 is confi gured with Automated Airborne Determination, ALT mode
selection occurs when liftoff is sensed. When the aircraft is on the ground, the transponder
automatically selects and displays STBY. The transponder does not respond to ATCRBS inter-
rogations when STBY is annunciated. When a delay time is set in the Confi guration Mode, the
GTX 327 waits this additional length of time after landing before changing to STBY mode.