Fujitsu AB G36LRTE Series Manuel de conception et de technique - Page 6

Parcourez en ligne ou téléchargez le pdf Manuel de conception et de technique pour {nom_de_la_catégorie} Fujitsu AB G36LRTE Series. Fujitsu AB G36LRTE Series 47 pages. Ceiling type
Également pour Fujitsu AB G36LRTE Series : Manuel de conception et de technique (47 pages)

Fujitsu AB G36LRTE Series Manuel de conception et de technique
2.

WIRELESS REMOTE CONTROLLER

FEATURES
Simple function setting
Setting of the air conditioner selection function is performed by remote controller.
Built-in timers
Select from four different timer programs (On/Off/Program/Sleep).
Program timer
The program timer operates the ON and OFF timer once within a 24 hour period.
Sleep timer
The sleep timer function automatically corrects the temperature thermostat setting according to
the time setting to prevent excessive cooling and heating while sleeping.
Cooling operation/dry operation
When the sleep timer is set, the set temperature
automatically rises 1°C every hour. The set
temperature can rise up to a maximum of 2°C.
Timer setting
60min.
1 °C
Switching remote controller signal code
Mixed-up
I.U.
I.U.
I.U.
I.U.
Code selector switch eliminates unit
being wrongly switched.
(Up to 4 codes can be set.)
*I.U.=Indoor unit
4 mode timer setup available (ON / OFF / PROGRAM / SLEEP).
Four kinds of timers. Easy operation.
Easy to change signal code (max. 4 units) by button operation.
2 °C
After code change
A
B
C
D
I.U.
I.U.
I.U.
I.U.
A
B
C
D
- (01 - 03) -
Heating operation
When the sleep timer is set, the set temperature
automatically drops 1°C every 30 minutes. The set
temperature can drop to a maximum of 4°C.
1 °C
2 °C
3 °C
30min.
60min.
90min.
Timer setting
4 °C