Fault Finding
Preliminary Electrical Systems Check
START
Isolate appliance
and carry out:
A: Earth Continuity
check.
NO
YES
Has inlet fuse blown?
NO
Inlet wiring
faulty.
Rectify any
fault.
Isolate appliance and
carry out:
B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.
Carry out:
C: Polarity check.
YES
PLUG (with cover removed)
Earth Wire
Green/Yellow
Neutral Wire
Blue
Brown
Blue
Brown
Carry out:
D: Resistance to
Earth check.
Electricity supply
should now be
satisfactory.
(face view)
( )
N
Blue
Green
Yellow
Green
Yellow
SOCKET
( )
E
L