AEG 6562 G Manuel d'instruction et d'installation - Page 3
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction et d'installation pour {nom_de_la_catégorie} AEG 6562 G. AEG 6562 G 10 pages.
Technical data
Type of gas
Adjusted for natural gas: 1,0 kPa
(test point pressure)
Q = Nominal gas consumption NG:
3,8 MJ/h
Small burner x 1=
Medium sized burner x 2= 6,8 MJ/h
Large sized burner x 1= 9,0 MJ/h
Total=
26,4 MJ/h
AUS/NZL:
Convertible to universal LPG (Propane):
2,75 kPa (test point pressure)
Q = Nominal gas consumption universal
LPG:
Small burner x 1=
3,8 MJ/h
Medium sized burner x 2= 6,8 MJ/h
Large sized burner x 1=
9,0 MJ/h
Total=
26,4 MJ/h
Hob is approved in accordance with
AS4551 (AG101) Australian Standard
Domestic Gas Cooking Appliances.
Electrical supply 230/240 V 50 Hz AC,
0,1A max
Ignition=
240 V / 0,6 VA generator
FSD
The unit features fully-secured gas taps
(thermo-fuse).
Radio-noise reduction
This unit observes the current EEC-
directive on radio noise reduction.
Material:
Stainless steel, ceramic
glass
Pansupport: Castiron enamelled
Built-in measurements:
Height:
60 mm
Width:
560 mm
Depth:
490 mm
Product measurements:
Height:
55 mm
Width:
580 mm
Depth:
510 mm
Weight:
13 kg
"THIS APPLIANCE MUST BE
CONNECTED TO AN EARTHED
GENERAL PURPOSE OUTLET."
18
Table of contents
Contents
For the user
Your new appliance ...................................................................................... 2
Safety information ........................................................................................ 4
Description of the product ......................................................................... 6
How to use .................................................................................................... 7
Burner ring............................................................................................ 8
Burner cover ......................................................................................... 8
Ignition electrode (A) ........................................................................... 8
Thermo Sensor (B) ............................................................................... 8
Ignition .................................................................................................. 9
Cleaning and maintenance ....................................................................... 10
Splashguard ........................................................................................ 10
Stainless steel surfaces ....................................................................... 11
The ceramic glass plate ...................................................................... 11
The gas burner .................................................................................... 12
Service
.................................................................................................. 19
For the installer
Mounting .................................................................................................. 13
Technical data ............................................................................................. 18
How to read the operating instructions:
1...
2...Step by step
Safety information
Page no
Hint and tips
Environmental information
3
3