... the residual heat indicator suddenly fails to operate except for
_ or h.
Check whether
– the "On/Off" switch was activated by mistake.
– the sensor fields may be partially covered by a damp cloth, liquid or
similar.
– the safety shut-down was activated.
... the letter _ or h is still displayed by the residual heat indicator
after switching off the cooking zones.
Check whether
– the cooking zone has only been on for a short time and is therefore
not yet hot enough.
If the cooking zone is hot, please ring customer service.
... a cooking zone cannot be switched off
Check whether
– the sensor switches may be partially covered by a damp cloth or by
liquid.
– the lock mechanism is switched on.
... a cooking zone cannot be switched on
Check whether
– the lock mechanism is switched on.
... the indicator f is flashing
Check whether
– the pan is located on the correct cooking zone,
– the diameter of the pan base is too small for the cooking zone,
– the pan is suitable for induction.
... _ appears on the display
Check whether
– the cooking zone has overheated.
switch off the appropriate cooking zone and let it cool down. Try
switching on the cooking zone again using a suitable pan after a few
minutes.
– the automatic switch-down for the cooking zone has triggered.
You can reactivate the cooking zone by switching it off and on brief-
ly.
... the power function cannot be switched on
– Switch off the cooking zone for approx. 10 minutes.
If this fault occurs repeatedly check whether
– the requisite ventilation area between the work surface and the unit
facing underneath it has been covered over.
– the requisite ventilation area (25 cm
ance was installed (see chapter "Installation").
2
) was observed when the appli-
73