Fujitsu BR5450 Manuel de démarrage rapide - Page 11

Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} Fujitsu BR5450. Fujitsu BR5450 22 pages. Blade server systems, fibre channel connection blade

8. Enter the ipaddrset command to set the IP address.
Follow the on-screen instructions and supply the correct information, as shown in the following example:
switch:admin > ipaddrset
Ethernet IP address [10.77.77.77]:10.32.53.47
Ethernet Subnetmask [255.255.255.0]:255.255.240.0
Fibre Channel IP Address [none]:
Fibre Channel Subnetmask [none]:
Gateway IP Address [0.0.0.0]: 10.32.48.1
DHCP [Off]:
IP address is being changed ... Done.
9. Enter the ipaddrshow command to verify that the IP address was correctly set.

Using the PRIMERGY BX900 Management Blade CLI to change system settings

Use the following steps to connect and modify the Embedded Switch Module IP address through the PRIMERGY
BX900 Management Blade (MMB) CLI.
NOTE
It is recommended that you set the IP address using the PRIMERGY BX900 Management Blade ServerView GUI
application because this enables centralized management of the Embedded Switch Module.
1. Establish a Telnet session to the PRIMERGY BX900 Management Blade (MMB) CLI.
NOTE
The MMB must be on the same network as the management workstation.
a. Type TELNET <chassis_IP> 3172 from a command prompt on a management workstation.
NOTE
The telnet must use port 3172.
The Telnet login screen for <chassis_IP> displays.
b. Use the MMB default username and password. The default is admin for the username and admin for the
password.
The Telnet menu for <chassis_IP> displays.
2. Use the following Telnet menu options to change the IP address of the selected Embedded Switch Module.
a. Select (3) Console Redirection from the following Console Menu.
--------------------------------
Console Menu
--------------------------------
(1) Management Agent
(2) Emergency Management Port
(3) Console Redirection
(4) TFTP update
(5) Logout
(6) Reboot Management Blade
(7) System Information Dump
(8) Command Line Interface
(9) Account Management
Enter selection: 3
10 of 20
Brocade 5450 Embedded Switch Module QuickStart Guide
Publication Number: 53-1001265-02