2 Server Unit SU x86

This section describes the Server Units SU300 and SU310. SE300(B) is equipped with an SU300 as the first Server
Unit. SE300, SE500 and SE700 can optionally be equipped with one or two additional Server Units SU300. SE310
is equipped with an SU310 as Server Unit.
i
Components and ports which are not used are not described below.
In the SU x86 the base system X2000 enables BS2000 to execute (in Native mode or on BS2000 VMs). Optionally
X2000 enables Linux/Windows systems to operate in parallel on XenVMs.
An SU300 occupies four height units (HUs) in the rack, an SU310 occupies two HUs.
Features
For SU300 16 models are available with up to 16 BS2000 processors. For SU310 there are 3 models with 4
processors (16 cores) each. Capacity on Demand permits temporary processor attachment.
Depending on the model, the size of the main memory (for BS2000 and for the base system X2000) is 32 to 128
GB in the basic configuration. These models can be enhanced to up to 512 GB (SU310) resp. 1504 GB (SU300)
or 2912 GB (SU300B).
For the input/output system the Server Unit contains two 2.5'' SAS (on SU310) resp. SATA (on SU300) hard
disks, each with a capacity of 600 GB in size in the basic configuration, which are mirrored.
The Server Unit contains a DVD-RW drive.
Fibre Channels operating at 8 or 16 Gbps are available for connecting peripherals.
At least one 4-port LAN card is connected on the Server Unit. The first two ports are used for the connection to
the Net Unit, and the other two can, if required, be used for BS2000 applications. Optionally LAN controllers
operating at 10 Gbps can also be used.
Each Server Unit is equipped with 4 power supply units. 2 + 2 redundancy in 2 phases is thus guaranteed. If one
phase fails completely, the Server Unit will continue to operate.
6