XCP Issues Fixed in Releases Earlier Than XCP
TABLE 6
ID
Description
RTIF1-
In the dual power feed system, when the
090108-002
power failure and the power recovery
occurred repeatedly on one line, all domains
will be forcibly powered off. And in the power
recovery from the forced power-off, a PSU
illegal configuration might be registered in the
error log and the power recovery might not be
started.
RTIF1-
When you execute the settelnet -c
090115-001
disable command, the Telnet service will be
stopped immediately. However, unless you
reset XSCF by using the rebootxscf(8)
command, you might fail in the subsequent
restart of the Telnet service.
RTIF1-
"Power recovery" message is output before
090122-001
a PSU has recovered.
RTIF1-
In a system connecting multiple hosts and one
090220-001
or more I/O units with RCI, the power-on
operation to one of those RCI hosts may not
power on any of the RCI I/O units.
RTIF1-
After replaced the motherboard unit, the RCI
090220-002
power interlocking setting restores to its
default value.
RTIF1-
Despite the normal status of ppp network
090427-001
interface for the XSCF-to-Solaris OS
communication, SNMP MIB notifies abnormal
(down) status.
RTIF1-
After the XSCF reset or switching, you cannot
090427-002
login to XSCF using the LDAP server.
RTIF1-
In the setting of the LDAP server, the number
090427-004
of characters which can be specified differs
between XSCF Web and XSCF Shell. On XSCF
Web, you can enter up to 128 characters.
RTIF1-
After you set https (using the self certificate
090430-001
authority) by XSCF and created a web server
certificate, https is not enabled.
1093
(Continued)
Workaround
You need to remove and insert the power
cable.
After you stopped the Telnet service, execute
the rebootxscf(8) command to reset XSCF.
After the "Power recovery" message is
output, wait 60 seconds before removing
power from another PSU.
All the RCI hosts shall be powered on.
If you have set the power interlocking to a
value other than the default, replace the
motherboard unit and then use the
setpwrmode(1M) command to set the power
interlocking setting again.
No workaround is available.
No workaround is available.
Log in to active XSCF with initial account and
execute the following command to re-import
the certificate chain.
'setldap -c <remote file>'
To set 129 characters or more, use XSCF Shell.
To set the self certificate authority, do not
specify a blank character.
Information About Software
21